Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  GIOVE, a shallow laboratory Ge-spectrometer with 100 μBq/kg sensitivity

Denz, T., Hakenmueller, J., Heusser, G., Hofacker, R., & Weber, M. (2013). GIOVE, a shallow laboratory Ge-spectrometer with 100 μBq/kg sensitivity. American Institute of Physics Conference Proceedings, 1549: 12. doi:10.1063/1.4818065.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
GioveAIP_proc2013.pdf (beliebiger Volltext), 1001KB
Name:
GioveAIP_proc2013.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:
ausblenden:
externe Referenz:
http://dx.doi.org/10.1063/1.4818065 (Verlagsversion)
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Denz , Tobias1, Autor
Hakenmueller, Janina1, Autor           
Heusser, Gerd1, Autor           
Hofacker , Reinhard1, Autor
Weber, Marc1, Autor           
Affiliations:
1Division Prof. Dr. Manfred Lindner, MPI for Nuclear Physics, Max Planck Society, ou_904549              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: A new germanium gamma spectrometer called GIOVE ( G ermanium spectrometer with I nner and O uter V eto) has been set up at the underground/shallow laboratory (15 m w.e.) of MPI-K. Its double plastic scintillator veto system and neutron moderation interlayer lower the background by more than one order of magnitude compared to the other existing spectrometer at this facility. The integral (40-2700 keV) background rate of about 290 counts (day kg)−1 is just a factor 4 to 8 above that of the GeMPI spectrometers operated at LNGS (3800 m w.e.) and thus proves that even under shallow overburden sub mBq/kg sensitivities are achievable. Extended material screening and neutron attenuation studies preceded the final design of the spectrometer. The technical realization of the spectrometer is described in detail with special emphasis on the inner veto system. For its optimisation a simulation model was developed for light collection on small low activity PMT’s under various geometrical conditions. Radon suppression is accomplished by employing a gas tight sample container and a nitrogen flushed glove-box system with an airlock. The active volume of the crystal was modelled by absorption scanning measurements and Monte Carlo simulations. The complete shield is implemented in a Geant4 based simulation framework.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2013-08-08
 Publikationsstatus: Online veröffentlicht
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1063/1.4818065
 Art des Abschluß: -

Veranstaltung

einblenden:
ausblenden:
Titel: LOW RADIOACTIVITY TECHNIQUES 2013 (LRT 2013)
Veranstaltungsort: Laboratori del Gran Sasso, Assergi, Italy
Start-/Enddatum: 2013-04-10 - 2013-04-12

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: American Institute of Physics Conference Proceedings
  Andere : AIP Conf. Proc.
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: New York : American Institute of Physics
Seiten: - Band / Heft: 1549 Artikelnummer: 12 Start- / Endseite: - Identifikator: ISSN: 0094-243X
CoNE: https://pure.mpg.de/cone/journals/resource/954928528968