English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Gadolinium-Enhanced Elliptically Reordered Three-Dimensional MR Angiography in the Assessment of Hand Vascularization Before Radial Artery Harvest for Coronary Artery Bypass Grafting: First Experience

Winterer, J., Ennker J, Scheffler, K., Rosendahl U, Schäfer O, Wanner M, Laubenberger, J., & Langer, M. (2001). Gadolinium-Enhanced Elliptically Reordered Three-Dimensional MR Angiography in the Assessment of Hand Vascularization Before Radial Artery Harvest for Coronary Artery Bypass Grafting: First Experience. Investigative Radiology, 36(9), 501-508. Retrieved from http://journals.lww.com/investigativeradiology/pages/articleviewer.aspx?year=2001issue=09000article=00001type=abstract.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Winterer, JT, Author
Ennker J, Scheffler, K1, Author           
Rosendahl U, Schäfer O, Wanner M, Laubenberger, J, Author
Langer, M, Author
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

Content

show
hide
Free keywords: -
 Abstract: rationale and objectives. To assess the suitability of contrast-enhanced magnetic resonance angiography (MRA) in the preoperative evaluation of hand vasculature in potential candidates for radial artery bypass grafting. methods. In 21 patients, gadobenate dimeglumine-enhanced, three-dimensional gradient-echo sequences of both hands were performed, as well as a Doppler ultrasound study with radial artery compression. Doppler findings were correlated with MRA, focusing on the assessment of anastomoses between the vascular bed of the ulnar and radial arteries. results. One individual had to be excluded because of accidentally disclosed metal foreign bodies. Sufficient depiction of the hand vasculature was achieved in the remainder. Seventeen patients had evidence of adequate collateral flow between the ulnar and radial artery supply on Doppler ultrasound. Three patients exhibited inadequate collateral flow, with angiographic signs of vessel occlusion or missing collaterals between the palmar arches. Two patients presented with stenosis or occlusion of the radial artery. Magnetic resonance angiograms displayed great variations in hand vasculature and collateral formation, with no mismatch compared with Doppler ultrasound results. conclusions. Contrast-enhanced MRA displays vascularization of the hand in detail and supplies ultrasound flow measurements for radial artery harvest, with high-resolution angiographic data about possible vessel variations and the presence of anastomoses between the radial or ulnar artery supply.

Details

show
hide
Language(s):
 Dates: 2001-09
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Investigative Radiology
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 36 (9) Sequence Number: - Start / End Page: 501 - 508 Identifier: -