Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Are TrueFISP images T2/T1-weighted?

Huang, T.-Y., Huang I-J, Chen C-Y, Scheffler, K., Chung, H.-W., & Cheng, H.-C. (2002). Are TrueFISP images T2/T1-weighted? Magnetic Resonance in Medicine, 48(4), 684-688. doi:10.1002/mrm.10260.

Item is

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Huang, T-Y, Autor
Huang I-J, Chen C-Y, Scheffler, K1, Autor           
Chung, H-W, Autor
Cheng, H-C, Autor
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Images acquired using the TrueFISP technique (true fast imaging with steady-state precession) are generally believed to exhibit T2/T1-weighting. In this study, it is demonstrated that with the widely used half-flip-angle preparation scheme, approaching the steady state requires a time length comparable to the scan time such that the transient-state response may dominate the TrueFISP image contrast. Two-dimensional images of the human brain were obtained using various phase-encoding matrices to investigate the transient-state signal behavior. Contrast between gray and white matter was found to change significantly from proton-density- to T2/T1-weighted as the phase-encoding matrix size increased, which was in good agreement with theoretical predictions. It is concluded that TrueFISP images in general exhibit T2/T1-contrast, but should be more appropriately regarded as exhibiting a transient-state combination of proton-density and T2/T1 contrast under particular imaging conditions. Interpretation of tissue characteristics from TrueFISP images in clinical practice thus needs to be exercised with caution.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2002-10
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: URI: http://onlinelibrary.wiley.com/doi/10.1002/mrm.10260/pdf
DOI: 10.1002/mrm.10260
BibTex Citekey: HuangHCSCC2002
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance in Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 48 (4) Artikelnummer: - Start- / Endseite: 684 - 688 Identifikator: -