English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Perfusion-based high-resolution fMRI in the primate brain using a novel vertical large-bore 7 Tesla setup

Pfeuffer, J., Steudel, T., Merkle, H., & Logothetis, N. (2004). Perfusion-based high-resolution fMRI in the primate brain using a novel vertical large-bore 7 Tesla setup. In ISMRM Workshop on Quantitative Cerebral Perfusion Imaging Using MRI: A Technical Perspective (pp. 108-109).

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Pfeuffer, J1, Author           
Steudel, T1, 2, Author           
Merkle, H3, Author           
Logothetis, NK1, Author           
Affiliations:
1Department Physiology of Cognitive Processes, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497798              
2Dept. Empirical Inference, Max Planck Institute for Intelligent System, Max Planck Society, ou_1497647              
3Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              

Content

show
hide
Free keywords: -
 Abstract: Functional MR imaging in monkeys promises a bridge between brain research in humans and the large body of systems neuroscience work in animals. Prerequisite for successful interspecies-comparisons, however, is a profound understanding of the neural events underlying the hemodynamic responses. Combined physiology and neuroimaging experiments made the first step in this direction by examining directly the relationship of cell activity to the BOLD signal [1]. The tight coupling between regional neural activity and blood flow, however, suggests that perfusion-based MRI may improve even further the electrophysiological investigations of the neurovascular coupling, as perfusion imaging measures cerebral blood flow (CBF) directly at the capillary level. Moreover, CBF changes and interleaved-acquired BOLD data can be combined to compute changes in oxygen consumption rate. Obtaining functional CBF maps with high spatial resolution is challenging, because the CBF signal is intrinsically low and the signal-to-noise ratio is critical. Here we report the first high-resolution CBF maps that were obtained with voxel sizes as small as 0.5 x 0.5 x 3 mm3 in the Macaca mulatta. High sensitivity was achieved by using a high magnetic field scanner and custom-made RF combination-coil designs. CBF maps and functional CBF data were acquired and compared with BOLD data in the macaque primary visual cortex.

Details

show
hide
Language(s):
 Dates: 2004-03
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: URI: http://www.ismrm.org/workshops/Perfusion_Imaging/
BibTex Citekey: 2529
 Degree: -

Event

show
hide
Title: ISMRM Workshop on Quantitative Cerebral Perfusion Imaging Using MRI: A Technical Perspective
Place of Event: Kyoto, Japan
Start-/End Date: -

Legal Case

show

Project information

show

Source 1

show
hide
Title: ISMRM Workshop on Quantitative Cerebral Perfusion Imaging Using MRI: A Technical Perspective
Source Genre: Proceedings
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: - Sequence Number: - Start / End Page: 108 - 109 Identifier: -