Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Texture and haptic cues in slant discrimination: Reliability-based cue weighting without statistically optimal cue combination

Rosas, P., Wagemans J, Ernst, M., & Wichmann, F. (2005). Texture and haptic cues in slant discrimination: Reliability-based cue weighting without statistically optimal cue combination. Journal of the Optical Society of America A, 22(5), 801-809. Retrieved from http://josaa.osa.org/DirectPDFAccess/2E1BCF03-BDB9-137E-C541C6B14AA1F5A7_83573.pdf?da=1id=83573seq=0CFID=44254280CFTOKEN=96368927.

Item is

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Rosas, P1, Autor           
Wagemans J, Ernst, MO2, Autor           
Wichmann, FA3, Autor           
Affiliations:
1Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              
2Research Group Multisensory Perception and Action, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497806              
3Department Empirical Inference, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497795              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: A number of models of depth cue combination suggest that the final depth percept results from a weighted average of independent depth estimates based on the different cues available. The weight of each cue in such an average is thought to depend on the reliability of each cue. In principle, such a depth estimation could be statistically optimal in the sense of producing the minimum variance unbiased estimator that can be constructed from the available information. Here we test such models using visual and haptic depth information. Different texture types produce differences in slant discrimination performance, providing a means for testing a reliability-sensitive cue combination model using texture as one of the cues to slant. Our results show that the weights for the cues were generally sensitive to their reliability, but fell short of statistically optimal combination—we find reliability-based re-weighting, but not statistically optimal cue combination.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2005-05
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Journal of the Optical Society of America A
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 22 (5) Artikelnummer: - Start- / Endseite: 801 - 809 Identifikator: -