English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Double average parallel steady-state free precession imaging: Optimized eddy current and transient oscillation compensation

Markl, M., Leupold J, Bieri O, Scheffler, K., & Hennig, J. (2005). Double average parallel steady-state free precession imaging: Optimized eddy current and transient oscillation compensation. Magnetic Resonance in Medicine, 54(4), 965-974. doi:10.1002/mrm.20615.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Markl, M, Author
Leupold J, Bieri O, Scheffler, K1, Author           
Hennig, J, Author
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

Content

show
hide
Free keywords: -
 Abstract: Balanced steady-state free precession (SSFP) imaging is sensitive to off-resonance effects, which can lead to considerable artifacts during a transient phase following magnetization preparation or steady-state interruption. In addition, nonlinear k-space encoding is required if contrast-relevant k-space regions need to be acquired at specific delays following magnetization preparation or for transient artifact reduction in cardiac-gated k-space segmented CINE imaging. Such trajectories are problematic for balanced SSFP imaging due to nonconstant eddy current effects and resulting disruption of the steady state. In this work, a novel acquisition strategy for balanced SSFP imaging is presented that utilizes scan time reduction by parallel imaging for optimized “double average” eddy current compensation and artifact reduction during the transient phase following steady-state storage and magnetization preparation. Double average parallel SSFP imaging was applied to k-space segmented CINE SSFP tagging as well as nongated centrically encoded SSFP imaging. Phantom and human studies exhibit substantial reduction in steady-state storage and eddy current artifacts while maintaining spatial resolution, signal-to-noise ratio, and similar total scan time of a standard SSFP acquisition. The proposed technique can easily be extended to other acquisition schemes that would benefit from nonlinear reordering schemes and/or rely on interruption of the balanced SSFP steady state.

Details

show
hide
Language(s):
 Dates: 2005-10
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: URI: http://onlinelibrary.wiley.com/doi/10.1002/mrm.20615/pdf
DOI: 10.1002/mrm.20615
BibTex Citekey: MarklLBSH2005
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 54 (4) Sequence Number: - Start / End Page: 965 - 974 Identifier: -