English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Combo acquisitions: Balancing scan time reduction and image quality

Mekle, R., Wu EX, Meckel S, Wetzel, S., & Scheffler, K. (2006). Combo acquisitions: Balancing scan time reduction and image quality. Magnetic Resonance in Medicine, 55(5), 1093-1105. doi:10.1002/mrm.20882.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Mekle, R, Author
Wu EX, Meckel S, Wetzel, SG, Author
Scheffler, K1, Author           
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

Content

show
hide
Free keywords: -
 Abstract: Recently a new technique for the combined acquisition of multicontrast images, termed “combo acquisition,” was introduced. In combo acquisitions, the three concepts of 1) variable acquisition parameters, 2) k-space data sharing, and 3) multicontrast imaging are systematically integrated to reduce MRI scan time and improve data utilization in a clinical setting. In this study, two-contrast and three-contrast spin-echo (SE) and turbo spin-echo (TSE) combo acquisition protocols that were designed and optimized in simulation experiments were implemented on a 1.5 T clinical scanner. Phantom and human brain data from volunteers and patients were acquired. Scan time reductions of 25–52 were achieved compared to standard acquisitions, largely confirming the simulation results. We evaluated the resulting images by quantitatively analyzing the preservation of contrast and the signal-to-noise ratio (SNR). In addition, data sets for 10 clinical cases obtained with TSE combo and corresponding standard acquisitions were graded by two experienced neuroradiologists in terms of the level of artifacts and image quality for comparison. Only minor image degradation with the combo scans was observed, indicating an inherent trade-off between scan time reduction and image quality. The specific aspects of combo acquisitions with respect to motion, flow, and k-space data weighting are discussed.

Details

show
hide
Language(s):
 Dates: 2006-05
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: URI: http://onlinelibrary.wiley.com/doi/10.1002/mrm.20882/pdf
DOI: 10.1002/mrm.20882
BibTex Citekey: MekleWMWS2006
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 55 (5) Sequence Number: - Start / End Page: 1093 - 1105 Identifier: -