  Fluoroscopic Contrast-Enhanced MR Angiography with a Magnetization-Prepared Steady-State Free Precession Technique in Peripheral Arterial Occlusive Disease

Huegli, R., Anschwanden M, Scheffler, K., & Bilecen, D. (2006). Fluoroscopic Contrast-Enhanced MR Angiography with a Magnetization-Prepared Steady-State Free Precession Technique in Peripheral Arterial Occlusive Disease. American Journal of Roentgenology, 187(1), 242-247. Retrieved from http://www.ajronline.org/content/187/1/242.long.

Item is

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Huegli, RW, Autor
Anschwanden M, Scheffler, K1, Autor           
Bilecen, D, Autor
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: OBJECTIVE. The objective of our study was to evaluate the feasibility of intraarterial (IA) near-real-time contrast-enhanced MR angiography (CE-MRA) with a frame rate of 1.3 frames per second in seven patients with lower extremity peripheral arterial occlusive disease (PAOD). For optimized background suppression, a modified 2D steady-state free precession (SSFP) technique with magnetization preparation and mask subtraction was developed. The femoropopliteal and infrapopliteal arteries were covered in two separate steps. Acceptable contrast-to-noise ratios were obtained, and road maps were reconstructed from the same data set. CONCLUSION. Mastering IA near-real-time CE-MRA, including road map reconstruction, with an SSFP technique in the lower extremity of patients with PAOD is an important building block toward successfully performing endovascular catheter MR-guided interventions.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2006-07
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: URI: http://www.ajronline.org/content/187/1/242.long
BibTex Citekey: HuegliASB2006
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: American Journal of Roentgenology
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 187 (1) Artikelnummer: - Start- / Endseite: 242 - 247 Identifikator: -