日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

登録内容を編集ファイル形式で保存
 
 
ダウンロード電子メール
  High-resolution fMRI of macaque V1

Goense, J., Zappe, A.-C., & Logothetis, N. (2007). High-resolution fMRI of macaque V1. Magnetic Resonance Imaging, 25(6), 740-747. doi:10.1016/j.mri.2007.02.013.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Goense, JBM1, 著者           
Zappe, A-C1, 著者           
Logothetis, NK1, 著者           
所属:
1Department Physiology of Cognitive Processes, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497798              

内容説明

表示:
非表示:
キーワード: -
 要旨: To understand the physiological mechanisms underlying the blood-oxygenation-level-dependent (BOLD) signal, the acquisition of data must be optimized to achieve the maximum possible spatial resolution and specificity. The term “specificity” implies the selective enhancement of signals originating in the parenchyma, and thus best reflecting actual neural activity. Such spatial specificity is a prerequisite for imaging aimed at the elucidation of interactions between cortical micromodules, such as columns and laminae. In addition to the optimal selection of functional magnetic resonance imaging pulse sequences, accurate superposition of activation patterns onto corresponding anatomical scans, preferably acquired during the same experimental session, is necessary. At high resolution, exact functional-to-structural registration is of critical importance, because even small differences in geometry, that arise when different sequences are used for functional and anatomical scans, can lead to misallocation of activ ation and erroneous interpretation of data. In the present study, we used spin-echo (SE) echo planar imaging (EPI) for functional scans, since the SE-BOLD signal is sensitive to the capillary response, together with SE-EPI anatomical reference scans. The combination of these acquisition methods revealed a clear spatial colocalization of the largest fractional changes with the Gennari line, suggesting peak activity in Layer IV. Notably, this very same layer coincided with the largest relaxivity changes as observed in steady-state cerebral blood volume measurements, using the intravascular agent monocrystalline iron oxide nanoparticles (MION).

資料詳細

表示:
非表示:
言語:
 日付: 2007-07
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Magnetic Resonance Imaging
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: 25 (6) 通巻号: - 開始・終了ページ: 740 - 747 識別子(ISBN, ISSN, DOIなど): -