  Real-Time Fetal Heart Monitoring in Biomagnetic Measurements Using Adaptive Real-Time ICA

Waldert, S., Bensch M, Bogdan M, Rosenstiel W, Schölkopf, B., Lowery CL, Eswaran, H., & Preissl, H. (2007). Real-Time Fetal Heart Monitoring in Biomagnetic Measurements Using Adaptive Real-Time ICA. IEEE Transactions on Biomedical Engineering, 54(10), 1867-1874. doi:10.1109/TBME.2007.895749.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Waldert, S1, Author           
Bensch M, Bogdan M, Rosenstiel W, Schölkopf, B2, Author           
Lowery CL, Eswaran, H, Author
Preissl, H, Author
Affiliations:
1Department Human Perception, Cognition and Action, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497797              
2Department Empirical Inference, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497795              

Content

show
hide
Free keywords: -
 Abstract: Electrophysiological signals of the developing fetal brain and heart can be investigated by fetal magnetoencephalography (fMEG). During such investigations, the fetal heart activity and that of the mother should be monitored continuously to provide an important indication of current well-being. Due to physical constraints of an fMEG system, it is not possible to use clinically established heart monitors for this purpose. Considering this constraint, we developed a real-time heart monitoring system for biomagnetic measurements and showed its reliability and applicability in research and for clinical examinations. The developed system consists of real-time access to fMEG data, an algorithm based on Independent Component Analysis (ICA), and a graphical user interface (GUI). The algorithm extracts the current fetal and maternal heart signal from a noisy and artifact-contaminated data stream in real-time and is able to adapt automatically to continuously varying environmental parameters. This algorithm has been na med Adaptive Real-time ICA (ARICA) and is applicable to real-time artifact removal as well as to related blind signal separation problems.

Details

show
hide
Language(s):
 Dates: 2007-09
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: IEEE Transactions on Biomedical Engineering
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 54 (10) Sequence Number: - Start / End Page: 1867 - 1874 Identifier: -