English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  MR-Based PET Attenuation Correction: Method and Validation

Hofmann, M., Steinke, F., Scheel V, Charpiat, G., Brady M, Schölkopf, B., & Pichler, B. (2007). MR-Based PET Attenuation Correction: Method and Validation.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Hofmann, M1, Author           
Steinke, F1, Author           
Scheel V, Charpiat, G1, Author           
Brady M, Schölkopf, B1, Author           
Pichler, BJ, Author
Affiliations:
1Department Empirical Inference, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497795              

Content

show
hide
Free keywords: -
 Abstract: PET/MR combines the high soft tissue contrast of Magnetic Resonance Imaging (MRI) and the functional information of Positron Emission Tomography (PET). For quantitative PET information, correction of tissue photon attenuation is mandatory. Usually in conventional PET, the attenuation map is obtained from a transmission scan, which uses a rotating source, or from the CT scan in case of combined PET/CT. In the case of a PET/MR scanner, there is insufficient space for the rotating source and ideally one would want to calculate the attenuation map from the MR image instead. Since MR images provide information about proton density of the different tissue types, it is not trivial to use this data for PET attenuation correction. We present a method for predicting the PET attenuation map from a given the MR image, using a combination of atlas-registration and recognition of local patterns. Using "leave one out cross validation" we show on a database of 16 MR-CT image pairs that our method reliably allows estimating the CT image from the MR image. Subsequently, as in PET/CT, the PET attenuation map can be predicted from the CT image. On an additional dataset of MR/CT/PET triplets we quantitatively validate that our approach allows PET quantification with an error that is smaller than what would be clinically significant. We demonstrate our approach on T1-weighted human brain scans. However, the presented methods are more general and current research focuses on applying the established methods to human whole body PET/MRI applications.

Details

show
hide
Language(s):
 Dates: 2007-11
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: URI: http://www.nss-mic.org/2007/program/ProgramBook.pdf
BibTex Citekey: 4623
 Degree: -

Event

show

Legal Case

show

Project information

show

Source

show