English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  SELOVS: Brain MRSI localization based on highly selective T1- and B1-insensitive outer-volume suppression at 3T

Henning, A., Schär, M., Schulte, R., Wilm, B., Pruessmann, K., & Boesiger, P. (2008). SELOVS: Brain MRSI localization based on highly selective T1- and B1-insensitive outer-volume suppression at 3T. Magnetic Resonance in Medicine, 59(1), 40-51. doi:10.1002/mrm.21374.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Henning, A1, Author           
Schär, M, Author
Schulte, RF, Author
Wilm, B, Author
Pruessmann, KP, Author
Boesiger, P, Author
Affiliations:
1Institute for Biomedical Engineering, University and ETH, Zurich, ou_persistent22              

Content

show
hide
Free keywords: -
 Abstract: In vivo, high-field MR spectroscopic imaging (MRSI) profits from signal-to-noise ratio (SNR) gain and increased spectral resolution. However, bandwidth limitations of slice-selective excitation and refocusing pulses lead to strong chemical-shift displacement at high field strength when using conventional MRSI localization based on PRESS. Consequential metabolic information, particularly of border regions such as cortical brain tissue, is distorted. In addition, lipid contamination remains a major confound. To address these problems it is proposed to abandon PRESS selection and rely on a novel scheme of highly selective T1- and B1-insensitive outer-volume suppression in combination with slice-selective spin-echo acquisition for brain MRSI. Multiple cycles of overlapping suppression slabs are applied with flip angles optimized to account for tissue-dependent T1 relaxation times and band crossings. Broadband frequency modulated saturation pulses with polynomial phase-response are utilized in order to minimize chemical-shift displacement. Efficacy of the outer-volume suppression sequence was simulated and evaluated in vitro and in vivo. Brain MRSI localization at 3T was significantly improved and reliable suppression of short-range lipid contamination enabled, leading to substantial enhancement of spectral quality, particularly in cortical tissue. Hence, the new method holds potential to expand the applicability of high-field MRSI to the entire brain.

Details

show
hide
Language(s):
 Dates: 2008-01
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1002/mrm.21374
BibTex Citekey: HenningSSWPB2008
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 59 (1) Sequence Number: - Start / End Page: 40 - 51 Identifier: -