Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Display of Dural Sinuses with Time-Resolved, Contrast-Enhanced Three-Dimensional MR Venography

Meckel, S., Glücker TM, Kretzschmar M, Scheffler, K., Radü, E.-W., & Wetzel, S. (2008). Display of Dural Sinuses with Time-Resolved, Contrast-Enhanced Three-Dimensional MR Venography. Cerebrovascular Diseases, 25(3), 217-224. doi:10.1159/000113859.

Item is

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Meckel, S, Autor
Glücker TM, Kretzschmar M, Scheffler, K1, Autor           
Radü, E-W, Autor
Wetzel, SG, Autor
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Background: Time-resolved (TR) contrast-enhanced 3D MR angiography has recently received considerable attention for the workup of cerebrovascular diseases, foremost dural arteriovenous fistula and arteriovenous malformation, and potentially for the evaluation of dural sinus thrombosis. Thereby, the dynamic visualization of cerebral vessels is enabled similar to the principle of digital subtraction angiography. Yet, its voxel size is relatively large due to an inherent trade-off between the desired spatial and temporal resolutions. The goal of this study was to evaluate whether the limited spatial resolution of TR MR venography (MRV) is sufficient to visualize dural venous sinuses. Methods: The prospective study included 20 patients without compromise of cerebral venous outflow. Two neuroradiologists independently graded the quality of visualization of 11 predefined dural venous sinuses on images of fast TR contrast-enhanced MRV (1.5 s/dataset; voxel size, 2 × 2 × 2.2 mm; acquisition time, 37.5 s) in comparison to time-of-flight (TOF) MRV (voxel size, 0.8 × 0.8 × 4 mm; acquisition time, 3 min 51 s) and steady-state contrast-enhanced 3D (VIBE) MRV (voxel size, 1.1 × 0.9 × 1.5 mm; acquisition time, 2 min 46 s). Results: The torcular Herophili (p < 0.001), left (p < 0.001) and right (p < 0.01) transverse sinus, and right jugular bulb (p < 0.05) were visualized better at TR MRV than at TOF MRV. For visualization of the small inferior sagittal sinus, TR MRV was inferior to VIBE (p < 0.001) and TOF (p < 0.05) sequences. The visibility of all other dural sinuses was equal. Conclusion: Despite the inferior spatial resolution, TR MRV depicted some large dural sinuses more clearly than TOF MRV. To overcome the visualization of smaller venous structures, TR MRV can be applied complementarily with high-resolution steady-state contrast-enhanced MRV.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2008-03
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Cerebrovascular Diseases
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 25 (3) Artikelnummer: - Start- / Endseite: 217 - 224 Identifikator: -