Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Assessment of muscle oxygenation with balanced SSFP: A quantitative signal analysis

Klarhöfer, M., Madörin P, Bilecen, D., & Scheffler, K. (2008). Assessment of muscle oxygenation with balanced SSFP: A quantitative signal analysis. Journal of Magnetic Resonance Imaging, 27(5), 1169-1174. doi:10.1002/jmri.21334.

Item is

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Klarhöfer, M, Autor
Madörin P, Bilecen, D, Autor
Scheffler, K1, Autor           
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Purpose To investigate the feasibility of balanced steady-state free precession (b-SSFP) for blood oxygenation level–dependent (BOLD) MRI during a short-term ischemia/reactive hyperemia (RH) experiment on human calf muscles. Materials and Methods To investigate contributions to the b-SSFP signal during an RH experiment, the relaxation times T1, T2, and Tmath image were quantified in an interleaved fashion. Data from soleus, gastrocnemius, and tibialis muscle groups of five healthy subjects were evaluated. Results During ischemia a decreased b-SSFP signal amplitude as well as a decrease in T2, Tmath image, and the initial intensity I0 was observed. RH provoked an overshoot of T2, Tmath image, and the b-SSFP signal. No paradigm-related changes in T1 were observed. Comparing the evolution of transverse relaxation times, initial intensity, and b-SSFP signal amplitude, we concluded that the measured b-SSFP signal in muscle tissue is not only determined by T2 variations but also significantly influenced by I0 changes. These I0 changes are attributed to spin density variations since inflow effects were suppressed by saturation bands. Conclusion b-SSFP signal changes during a RH paradigm cannot unambiguously be assigned to oxygenation changes. Therefore, care has to be taken with their interpretation.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2008-05
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: URI: http://onlinelibrary.wiley.com/doi/10.1002/jmri.21334/pdf
DOI: 10.1002/jmri.21334
BibTex Citekey: KlarhoferMBS2008
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Journal of Magnetic Resonance Imaging
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 27 (5) Artikelnummer: - Start- / Endseite: 1169 - 1174 Identifikator: -