Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Quantitative magnetic resonance spectroscopy in the entire human cervical spinal cord and beyond at 3T

Henning, A., Schär M, Kollias SS, Boesiger, P., & Dydak, U. (2008). Quantitative magnetic resonance spectroscopy in the entire human cervical spinal cord and beyond at 3T. Magnetic Resonance in Medicine, 59(6), 1250–1258. doi:10.1002/mrm.21578.

Item is

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Henning, A1, Autor           
Schär M, Kollias SS, Boesiger, P, Autor
Dydak, U, Autor
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Quantitative magnetic resonance spectroscopy (MRS) amends differential diagnostics of neurological pathology. However, due to technical challenges, it has rarely been applied to the spinal cord and has mainly been restricted to the very upper part of the cervical spine. In this work, an improved acquisition protocol is proposed that takes technical problems as strong magnetic field inhomogeneities, pulsatile flow of the cerebrospinal fluid (CSF), and small voxel size into account. For that purpose, inner-volume saturated point-resolved spectroscopy sequence (PRESS) localization, ECG triggering, and localized higher-order shimming and F0 determination, based on high-resolution cardiac-triggered static magnetic field B0 mapping, are combined. For inner-volume saturation a highly selective T1- and B1-insensitive outer-volume suppression (OVS) sequence based on broadband RF pulses with polynomial-phase response (PPR) is used. Validation is performed in healthy volunteers and patients with multiple sclerosis and intramedullary tumors. The applicability of spinal cord MRS is extended to the entire cervical spine. Spectral quality and its consistency are improved. In addition, high quality MRS patient data from a lesion that occluded the spinal canal in the thoracic spinal cord could be acquired. A quantitative analysis of patient spectra and spectra from healthy volunteers at different positions along the spinal cord underlines the diagnostic value of spinal cord MRS.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2008-06
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: URI: http://onlinelibrary.wiley.com/doi/10.1002/mrm.21578/pdf
DOI: 10.1002/mrm.21578
BibTex Citekey: HenningSKBD2008
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance in Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 59 (6) Artikelnummer: - Start- / Endseite: 1250–1258 Identifikator: -