English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Automated Correction of Fast Motion Artifacts for Two-photon Imaging of Awake Animals

Greenberg, D., & Kerr, J. (2009). Automated Correction of Fast Motion Artifacts for Two-photon Imaging of Awake Animals. Journal of Neuroscience Methods, 176(1), 1-15. doi:10.1016/j.jneumeth.2008.08.020.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Greenberg, DS1, Author           
Kerr, JND1, Author           
Affiliations:
1Research Group Neural Population Imaging, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497807              

Content

show
hide
Free keywords: -
 Abstract: Two-photon imaging of bulk-loaded calcium dyes can record action potentials (APs) simultaneously from dozens of spatially resolved neurons in vivo. Extending this technique to awake animals, however, has remained technically challenging due to artifacts caused by brain motion. Since in two-photon excitation microscopes image pixels are captured sequentially by scanning a focused pulsed laser across small areas of interest within the brain, fast displacements of the imaged area can distort the image nonuniformly. If left uncorrected, brain motion in awake animals will cause artifactual fluorescence changes, masking the small functional fluorescence increases associated with AP discharge. We therefore present a procedure for detection and correction of both fast and slow displacements in two-photon imaging of awake animals. Our algorithm, based on the Lucas–Kanade framework, operates directly on the motion-distorted imaging data, requiring neither external signals such as heartbeat nor a distortion-free templa te image. Motion correction accuracy was tested in silico over a wide range of simplified and realistic displacement trajectories and for multiple levels of fluorescence noise. Accuracy was confirmed in vivo by comparing solutions obtained from red and green fluorophores imaged simultaneously. Finally, the accuracy of AP detection from motion-displaced bulk-loaded calcium imaging is evaluated with and without motion correction, and we conclude that accurate motion correction as achieved by this procedure is both necessary and sufficient for single AP detection in awake animals.

Details

show
hide
Language(s):
 Dates: 2009-01
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Journal of Neuroscience Methods
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 176 (1) Sequence Number: - Start / End Page: 1 - 15 Identifier: -