English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Using the GRAPPA operator and the generalized sampling theorem to reconstruct undersampled non-Cartesian data

Seiberlich, N., Breuer FA, Ehses, P., Moriguchi H, Blaimer M, Jakob, P., & Griswold, M. (2009). Using the GRAPPA operator and the generalized sampling theorem to reconstruct undersampled non-Cartesian data. Magnetic Resonance in Medicine, 61(3), 705-715. doi:10.1002/mrm.21891.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Seiberlich, N, Author
Breuer FA, Ehses, P1, Author           
Moriguchi H, Blaimer M, Jakob, PM, Author
Griswold, MA, Author
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

Content

show
hide
Free keywords: -
 Abstract: As expected from the generalized sampling theorem of Papoulis, the use of a bunched sampling acquisition scheme in conjunction with a conjugate gradient (CG) reconstruction algorithm can decrease scan time by reducing the number of phase-encoding lines needed to generate an unaliased image at a given resolution. However, the acquisition of such bunched data requires both modified pulse sequences and high gradient performance. A novel method of generating the “bunched” data using self-calibrating GRAPPA operator gridding (GROG), a parallel imaging method that shifts data points by small distances in k-space (with Δk usually less than 1.0, depending on the receiver coil) using the GRAPPA operator, is presented here. With the CG reconstruction method, these additional “bunched” points can then be used to reconstruct an image with reduced artifacts from undersampled data. This method is referred to as GROG-facilitated bunched phase encoding (BPE), or GROG-BPE. To better understand how the patterns of bunched points, maximal blip size, and number of bunched points affect the reconstruction quality, a number of simulations were performed using the GROG-BPE approach. Finally, to demonstrate that this method can be combined with a variety of trajectories, examples of images with reduced artifacts reconstructed from undersampled in vivo radial, spiral, and rosette data are shown.

Details

show
hide
Language(s):
 Dates: 2009-03
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: URI: http://onlinelibrary.wiley.com/doi/10.1002/mrm.21891/pdf
DOI: 10.1002/mrm.21891
BibTex Citekey: SeiberlichBEMBJG2009
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 61 (3) Sequence Number: - Start / End Page: 705 - 715 Identifier: -