  Cerebral Venous Thrombosis: Diagnostic Accuracy of Combined, Dynamic and Static, Contrast-Enhanced 4D MR Venography

Meckel, S., Reisinger C, Bremerich J, Damm D, Wolbers M, Engelter S, Scheffler, K., & Wetzel, S. (2010). Cerebral Venous Thrombosis: Diagnostic Accuracy of Combined, Dynamic and Static, Contrast-Enhanced 4D MR Venography. AJNR American Journal of Neuroradiology, 31(3), 527-535. doi:10.3174/ajnr.A1869.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Meckel, S, 著者
Reisinger C, Bremerich J, Damm D, Wolbers M, Engelter S, Scheffler, K1, 著者           
Wetzel, SG, 著者
所属:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

内容説明

表示:
非表示:
キーワード: -
 要旨: BACKGROUND AND PURPOSE: MR including MRV is an established method to diagnose CVT. However, it remains unsettled which MR imaging modalities offer the highest diagnostic accuracy. We evaluated the accuracy of a combined, dynamic (1.5 seconds per dataset) and static (voxel size, 1.1 x 0.9 x 1.5 mm), contrast-enhanced MRV method (combo-4D MRV) relative to other established MR/MRV modalities. MATERIALS AND METHODS: A total of 39 patients with CVT (n = 20) and control subjects (n = 19) underwent combo-4D MRV, 2D TOF MRV, GRE imaging, and T2W imaging. For these modalities, diagnostic accuracy (ROCs) for CVT affecting 53 out of 234 predefined venous segments was determined. Sensitivity and specificity were separately calculated for different stages of CVT (acute/subacute/chronic). RESULTS: Combo-4D MRV showed the highest accuracy (AUC, 0.99 [95 CI, 0.97-1.0]; sensitivity, 97 [84-100]) for thrombosed dural sinuses. For all thrombosed segments including cortical veins, its sensitivity was best (76 [64-84]; AUC, 0.92 [0.88-0.96]), followed by TOF MRV (72 [59-81]; AUC, 0.93 [0.88-0.97]). Even for chronic CVT, it showed a relatively high sensitivity of 67 (30-90). For thrombosed cortical veins alone, GRE images achieved the highest sensitivity (66 [46-81]; AUC, 0.88 [0.78-0.97]). Specificities of all modalities ranged from 96 to 99. CONCLUSIONS: Combo-4D MRV showed an excellent accuracy for the diagnosis of dural sinus thrombosis. The analysis of dynamic patterns of contrast enhancement in dural sinuses appeared useful to identify chronic thrombosis. To diagnose thrombosed cortical veins, GRE images should primarily be analyzed.

資料詳細

表示:
非表示:
言語:
 日付: 2010-03
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): URI: http://www.ajnr.org/content/31/3/527.long
DOI: 10.3174/ajnr.A1869
BibTex参照ID: MeckelRBDWESW2010
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: AJNR American Journal of Neuroradiology
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: 31 (3) 通巻号: - 開始・終了ページ: 527 - 535 識別子(ISBN, ISSN, DOIなど): -