  23Na MR Imaging at 7 T after Knee Matrix–associated Autologous Chondrocyte Transplantation Preliminary Results

Trattnig, S., Welsch GH, Juras V, Szomolanyi P, Mayerhoefer ME, Stelzeneder D, Mamisch TC, Bieri O, Scheffler, K., & Zbýn, S. (2010). 23Na MR Imaging at 7 T after Knee Matrix–associated Autologous Chondrocyte Transplantation Preliminary Results. Radiology, 257(1), 175-184. doi:10.1148/radiol.10100279.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Trattnig, S, Author
Welsch GH, Juras V, Szomolanyi P, Mayerhoefer ME, Stelzeneder D, Mamisch TC, Bieri O, Scheffler, K1, Author           
Zbýn, S, Author
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

Content

show
hide
Free keywords: -
 Abstract: Purpose: To evaluate the feasibility of sodium 7-T magnetic resonance (MR) imaging in repaired tissue and native cartilage of patients after matrix-associated autologous chondrocyte transplantation (MACT) and compare results with delayed gadolinium-enhanced MR imaging of cartilage (dGEMRIC) at 3 T. Materials and Methods: Ethical approval was provided by the local ethics committee; written informed consent was obtained from all patients. Six women and six men (mean age, 32.8 year ± 8.2 [standard deviation] and 32.3 years ± 12.7, respectively) were included. Mean time between MACT and MR was 56 months ± 28. A variable three-dimensional (3D) gradient-echo (GRE) dual–flip-angle technique was used for T1 mapping before and after contrast agent administration at 3 T. All patients were also examined at 7 T (mean delay, 70.5 days ± 80.1). A sodium 23–only transmit-receive knee coil was used with the 3D GRE sequence. A statistical analysis of variance and Pearson correlation were applied. Results: Mean signal-to-noise ratio (SNR) was 24 in native cartilage and was 16 in transplants (P < .001). Mean sodium signal intensities normalized with the reference sample were 174 ± 53 and 267 ± 42 for repaired tissue in the cartilage transplant and healthy cartilage, respectively (P < .001). Mean postcontrast T1 values were 510 msec ± 195 and 756 msec ± 188 for repaired tissue and healthy cartilage, respectively (P = .005). Mean score of MR observation of cartilage repair tissue was 75 ± 14. Association between postcontrast T1 and normalized sodium signal values showed a high Pearson correlation coefficient (R) of 0.706 (P = .001). A high correlation of R = 0.836 (P = .001) was found between ratios of normalized sodium values and ratios of T1 postcontrast values. Conclusion: With the modified 3D GRE sequence at 7 T, a sufficiently high SNR in sodium images was achieved, allowing for differentiation of repaired tissue from native cartilage after MACT. A strong correlation was found between sodium imaging and dGEMRIC in patients after MACT.

Details

show
hide
Language(s):
 Dates: 2010-10
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: URI: http://radiology.rsna.org/content/257/1/175
DOI: 10.1148/radiol.10100279
BibTex Citekey: TrattnigWJSMSMBSZ2010
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Radiology
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 257 (1) Sequence Number: - Start / End Page: 175 - 184 Identifier: -