Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Influence of MT effects on T2 quantification with 3D balanced steady-state free precession imaging

Crooijmans, H., Gloor M, Bieri, O., & Scheffler, K. (2011). Influence of MT effects on T2 quantification with 3D balanced steady-state free precession imaging. Magnetic Resonance in Medicine, 65(1), 195–201. doi:10.1002/mrm.22326.

Item is

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Crooijmans, HJA, Autor
Gloor M, Bieri, O, Autor
Scheffler, K1, Autor           
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Signal from balanced steady-state free precession is affected by magnetization transfer. To investigate the possible effects on derived T2 values using variable nutation steady-state free precession, magnetization transfer-effects were modulated by varying the radiofrequency pulse duration only or in combination with variable pulse repetition time. Simulations reveal a clear magnetization transfer dependency of T2 when decreasing radiofrequency pulse duration, reaching maximal deviation of 34.6 underestimation with rectangular pulses of 300 μs duration. The observed T2 deviation evaluated in the frontal white matter and caudate nucleus shows a larger underestimation than expected by numerical simulations. However, this observed difference between simulation and measurement is also observed in an aqueous probe and can therefore not be attributed to magnetization transfer: it is an unexpected sensitivity of derived T2 to radiofrequency pulse modulation. As expected, the limit of sufficiently long radiofrequency pulse duration to suppress magnetization transfer-related signal modulations allows for proper T2 estimation with variable nutation steady-state free precession.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2011-01
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: URI: http://onlinelibrary.wiley.com/doi/10.1002/mrm.22326/pdf
DOI: 10.1002/mrm.22326
BibTex Citekey: CrooijmansGBS2011
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance in Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 65 (1) Artikelnummer: - Start- / Endseite: 195–201 Identifikator: -