  Assessment of MR compatibility of a PET insert developed for simultaneous multiparametric PET/MR imaging on an animal system operating at 7 T

Wehrl, H., Judenhofer MS, Thielscher, A., Martirosian P, Schick, F., & Pichler, B. (2011). Assessment of MR compatibility of a PET insert developed for simultaneous multiparametric PET/MR imaging on an animal system operating at 7 T. Magnetic Resonance in Medicine, 65(1), 269-279. doi:10.1002/mrm.22591.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Wehrl, HF, 著者
Judenhofer MS, Thielscher, A1, 著者           
Martirosian P, Schick, F, 著者
Pichler, BJ, 著者
所属:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

内容説明

表示:
非表示:
キーワード: -
 要旨: The combination of positron emission tomography and MR in one system is currently emerging and opens up new domains in the functional examinations of living systems. This article reports on relevant influences of a positron emission tomography insert on MR imaging. The basic conditions of main magnetic field and RF field homogeneity were measured as well as image quality and signal-to-noise ratio when applying the usual MR sequence types including echo-planar techniques. Moreover, the influence of the positron emission tomography insert on the RF noise level and on RF interferences was measured by comparing results achieved with and without the positron emission tomography insert. The temporal stability of EPI imaging with and without the positron emission tomography insert was assessed. Small but significant decreases in the signal-to-noise ratio were revealed when the positron emission tomography insert was present, whereas B(0) and B(1) homogeneity as well as RF noise level were not adversely affected. A higher signal intensity drift was found for EPI imaging studies; however, this can be compensated by post processing. In summary, this study shows that positron emission tomography inserts can be designed for and used within an MR system practically, without substantially affecting the MR image quality.

資料詳細

表示:
非表示:
言語:
 日付: 2011-01
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): URI: http://onlinelibrary.wiley.com/doi/10.1002/mrm.22591/pdf
DOI: 10.1002/mrm.22591
BibTex参照ID: WehrlJTMSP2011
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Magnetic Resonance in Medicine
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: 65 (1) 通巻号: - 開始・終了ページ: 269 - 279 識別子(ISBN, ISSN, DOIなど): -