  Improved radial GRAPPA calibration for real-time free-breathing cardiac imaging

Seiberlich, N., Ehses, P., Duerk J, Gilkeson, R., & Griswold, M. (2011). Improved radial GRAPPA calibration for real-time free-breathing cardiac imaging. Magnetic Resonance in Medicine, 65(2), 492-505. doi:10.1002/mrm.22618.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Seiberlich, N, Author
Ehses, P1, Author           
Duerk J, Gilkeson, R, Author
Griswold, M, Author
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

Content

show
hide
Free keywords: -
 Abstract: To generate real-time, nongated, free-breathing cardiac images, the undersampled radial trajectory combined with parallel imaging in the form of radial GRAPPA has shown promise. However, this method starts to fail at high undersampling factors due to the assumptions that must be made for the purposes of calibrating the GRAPPA weight sets. In this manuscript, a novel through-time radial GRAPPA calibration scheme is proposed which greatly improves image quality for the high acceleration factors required for real-time cardiac imaging. This through-time calibration method offers better image quality than standard radial GRAPPA, but it requires many additional calibration frames to be acquired. By combining the through-time calibration method proposed here with the standard through-k-space radial GRAPPA calibration method, images with high acceleration factors can be reconstructed using few calibration frames. Both the through-time and the hybrid through-time/through-k-space methods are investigated to determine the most advantageous calibration parameters for an R = 6 in vivo short-axis cardiac image. Once the calibration parameters have been established, they are then used to reconstruct several in vivo real-time, free-breathing cardiac datasets with temporal resolutions better than 45 msec, including one with a temporal resolution of 35 msec and an in-plane resolution of 1.56 mm2.

Details

show
hide
Language(s):
 Dates: 2011-02
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: URI: http://onlinelibrary.wiley.com/doi/10.1002/mrm.22618/pdf
DOI: 10.1002/mrm.22618
BibTex Citekey: SeiberlichEDGG2011
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 65 (2) Sequence Number: - Start / End Page: 492 - 505 Identifier: -