  Multislice 2D spin echo imaging using adapted readout gradients for compensation of BO inhomogeneities and gradient nonlinearities

Blumhagen, J., Ladebeck R, Fenchel, M., & Scheffler, K. (2011). Multislice 2D spin echo imaging using adapted readout gradients for compensation of BO inhomogeneities and gradient nonlinearities. Poster presented at 28th Annual Scientific Meeting ESMRMB 2011, Leipzig, Germany.

Item is

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Blumhagen, JO, Autor
Ladebeck R, Fenchel, M, Autor
Scheffler, K1, Autor           
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Purpose/Introduction: In whole-body MR/PET, the limitation of an MR-based axial field-of-view (FoV) due to B0 inhomogeneities and gradient nonlinearities [1,2] may cause a truncation of the MR data and has therefore potential impact on the attenuation correction [3]. Furthermore, a large FoV may also be relevant in MR-based interventional applications, e.g. radiotherapy and biopsy. Recently, the feasibility of an axial extension of the MR-based FoV using a gradient field that compensates the B0 inhomogeneities has been shown [4]. However, the optimal gradient strength is space-dependent and therefore does not achieve optimal distortion reduction in all slices. In this work we developed a multislice 2D spin-echo-based sequence that calculates and adapts the readout (RO) gradient for each slice position automatically and offers an extended FoV in multiple slices during one single scan. Subjects and Methods: Distortions due to B0 inhomogeneities and gradient nonlinearities in 2DFT SE frequency encoding can be reduced by using an adapted space-dependent readout gradient: GRO (x,y,z) = - δB0(x,y,z) / c(x,y,z), where δB0 is the B0 inhomogeneity and c is the relative error in the gradient field. Field deviations in the main magnetic field and the gradient field were quantified as described in [4]. A multislice 2D spin-echo-based sequence was developed to calculate and adapt the optimal RO gradient strength and polarity for each slice position automatically (Fig. 1).

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2011-10
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: URI: http://www.esmrmb.org/index.php?id=/en/index/esmrmb_2011_congress.htm
DOI: 10.1007/s10334-011-0268-5
BibTex Citekey: BlumhagenLFS2011
 Art des Abschluß: -

Veranstaltung

einblenden:
ausblenden:
Titel: 28th Annual Scientific Meeting ESMRMB 2011
Veranstaltungsort: Leipzig, Germany
Start-/Enddatum: -

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle

einblenden: