  First Results on Patients and Phantoms of a Fully Integrated Clinical Whole-Body PET/MRI

Schmidt, H., Schwenzer N, Bezrukov, I., Kolb A, Mantlik, F., Kupferschläger J, Lois C, Sauter A, Brendle C, Pfannenberg, C., & Pichler, B. (2011). First Results on Patients and Phantoms of a Fully Integrated Clinical Whole-Body PET/MRI. Talk presented at 2011 IEEE Nuclear Science Symposium, Medical Imaging Conference (NSS-MIC 2011). Valencia, Spain.

Item is

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Schmidt, H, Autor
Schwenzer N, Bezrukov, I1, Autor           
Kolb A, Mantlik, F1, Autor           
Kupferschläger J, Lois C, Sauter A, Brendle C, Pfannenberg, C, Autor
Pichler, BJ, Autor
Affiliations:
1Department Empirical Inference, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497795              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: First clinical fully integrated whole-body PET/MR scanners are just entering the field. Here, we present studies toward quantification accuracy and variation within the PET field of view of small lesions from our BrainPET/MRI, a dedicated clinical brain scanner which was installed three years ago in Tbingen. Also, we present first results for patient and phantom scans of a fully integral whole-body PET/MRI, which was installed two months ago at our department. The quantification accuracy and homogeneity of the BrainPET-Insert (Siemens Medical Solutions, Germany) installed inside the magnet bore of a clinical 3T MRI scanner (Magnetom TIM Trio, Siemens Medical Solutions, Germany) was evaluated by using eight hollow spheres with inner diameters from 3.95 to 7.86 mm placed at different positions inside a homogeneous cylinder phantom with an 9:1 and 6:1 sphere to background ratio. The quantification accuracy for small lesions at different positions in the PET FoV shows a standard deviation of up to 11 and is acceptable for quantitative brain studies where the homogeneity of quantification on the entire FoV is essental. Image quality and resolution of the new Siemens whole-body PET/MR system (Biograph mMR, Siemens Medical Solutions, Germany) was evaluated according to the NEMA NU2 2007 protocol using a body phantom containing six spheres with inner diameter from 10 to 37 mm at sphere to background ratios of 8:1 and 4:1 and the F-18 point sources located at different positions inside the PET FoV, respectively. The evaluation of the whole-body PET/MR system reveals a good PET image quality and resolution comparable to state-of-the-art clinical PET/CT scanners. First images of patient studies carried out at the whole-body PET/MR are presented highlighting the potency of combined PET/MR imaging.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2011-10
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: URI: http://www.nss-mic.org/2011/program/ListProgramDB.asp?session=J2
BibTex Citekey: SchmidtSBKMKLSBPP2011
 Art des Abschluß: -

Veranstaltung

einblenden:
ausblenden:
Titel: 2011 IEEE Nuclear Science Symposium, Medical Imaging Conference (NSS-MIC 2011)
Veranstaltungsort: Valencia, Spain
Start-/Enddatum: -

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle

einblenden: