English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Fast diffusion-weighted steady state free precession imaging of in vivo knee cartilage

Bieri, O., Ganter C, Welsch GH, Trattnig S, Mamisch, T., & Scheffler, K. (2012). Fast diffusion-weighted steady state free precession imaging of in vivo knee cartilage. Magnetic Resonance in Medicine, 67(3), 691–700. doi:10.1002/mrm.23061.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Bieri, O, Author
Ganter C, Welsch GH, Trattnig S, Mamisch, TC, Author
Scheffler, K1, Author           
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

Content

show
hide
Free keywords: -
 Abstract: Quantification of molecular diffusion with steady state free precession (SSFP) is complicated by the fact that diffusion effects accumulate over several repetition times (TR) leading to complex signal dependencies on transverse and longitudinal magnetization paths. This issue is commonly addressed by setting TR > T2, yielding strong attenuation of all higher modes, except of the shortest ones. As a result, signal attenuation from diffusion becomes T2 independent but signal-to-noise ratio (SNR) and sequence efficiency are remarkably poor. In this work, we present a new approach for fast in vivo steady state free precession diffusion-weighted imaging of cartilage with TR << T2 offering a considerable increase in signal-to-noise ratio and sequence efficiency. At a first glance, prominent coupling between magnetization paths seems to complicate quantification issues in this limit, however, it is observed that diffusion effects become rather T2(ΔD ∼ 1/10 ΔT2) but not T1 independent (ΔD ∼ 1/2 ΔT1) for low flip angles α ∼ 10 − 15°. As a result, fast high-resolution (0.35 × 0.35 − 0.50 × 0.50 mm2 in-plane resolution) quantitative diffusion-weighted imaging of human articular cartilage is demonstrated at 3.0 T in a clinical setup using estimated T1 and T2 or a combination of measured T1 and estimated T2 values.

Details

show
hide
Language(s):
 Dates: 2012-03
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: URI: http://onlinelibrary.wiley.com/doi/10.1002/mrm.23061/pdf
DOI: 10.1002/mrm.23061
BibTex Citekey: BieriGWTMS2011
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 67 (3) Sequence Number: - Start / End Page: 691–700 Identifier: -