Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Active Integrated Tracking Detectors for MRI-Guided Interventions

Anders, J., Ortmanns M, Scheffler, K., & Boero, G. (2012). Active Integrated Tracking Detectors for MRI-Guided Interventions. Talk presented at 46. Jahrestagung der Deutschen Gesellschaft für Biomedizinische Technik (BMT 2012). Jena, Germany.

Item is

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Anders, J, Autor
Ortmanns M, Scheffler, K1, Autor           
Boero, G, Autor
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Introduction Thanks to its three-dimensional imaging capabilities with excellent soft-tissue contrast, magnetic resonance imaging is gaining interest as a tool for guided interventions. All active tracking detectors currently used for the positioning of in-terventional devices during MRI-guided procedures use hand-wound detection coils with external electronics. Methods We use standard CMOS technology to manufacture fully-integrated NMR magnetometer chips which can be attached to interventional devices in order to determine their position during MRI-guided interventions. The chips co-integrate an NMR detection coil and a complete downconversion receiver on the same die. The detectors can work with dedicated, permanent samples or can utilize the chip environment as sample. Then, knowing the applied gradient strength and measuring the local Larmor frequency it is possible to determine the chip position and thereby also the position of the interventional device it is attached to. Results We have characterized a fully-integrated CMOS tracking detector with a size of 1 × 1.9 × 0.8 mm3, which can be used with medium-size catheters. The design has been successfully interfaced with a standard clinical scanner and achieves an isotropic spatial resolution of 0.15 mm in a measuring time of 100 ms. Conclusion and outlook We have presented and previously published [1] a fully-integrated tracking detector with a state-of-the-art performance in terms of spatial resolution. Currently, we are designing an updated version of the previous chip with a reduced size to make it suitable with the use in smaller size catheters. Apart from their high-reproducibility, and low manufacturing costs for large-volume fabrication one of the biggest advantages of the fully-integrated tracking devices is their on-chip LO generation and frequency downconversion which removes the need for high-frequency connections through the human body and thereby allows for an effective filtering of signals induced in cables during excitation.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2012-08
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: URI: http://conference.vde.com/bmt-2012/programm2012/seiten/default.aspx
DOI: 10.1515/bmt-2012-4407
BibTex Citekey: AndersOSB2012
 Art des Abschluß: -

Veranstaltung

einblenden:
ausblenden:
Titel: 46. Jahrestagung der Deutschen Gesellschaft für Biomedizinische Technik (BMT 2012)
Veranstaltungsort: Jena, Germany
Start-/Enddatum: -

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle

einblenden: