  IR TrueFISP with a golden-ratio-based radial readout: Fast quantification of T1, T2, and proton density

Ehses, P., Seiberlich N, Ma D, Breuer FA, Jakob PM, Griswold, M., & Gulani, V. (2013). IR TrueFISP with a golden-ratio-based radial readout: Fast quantification of T1, T2, and proton density. Magnetic Resonance in Medicine, 69(1), 71–81. doi:10.1002/mrm.24225.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Ehses, P1, Author           
Seiberlich N, Ma D, Breuer FA, Jakob PM, Griswold, MA, Author
Gulani, V, Author
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

Content

show
hide
Free keywords: -
 Abstract: A promising approach for the simultaneous quantification of relative proton density (M0), T1, and T2 is the inversion-recovery TrueFISP sequence, consisting of an inversion pulse followed by a series of balanced steady-state free precession acquisitions. Parameters can then be obtained from a mono-exponential fit to the series of images. However, a segmented acquisition is usually necessary, which increases the total acquisition time considerably. The goal of this study is to obtain M0, T1, and T2 maps using a single-shot acquisition, with T1 and T2 measurements in brain that are consistent with the published literature, with a 20-fold speed improvement over the segmented approach, and at a clinically relevant spatial resolution. To this end, a single-shot inversion-recovery TrueFISP sequence was combined with a radial view-sharing technique. The parameters M0, T1, and T2 were then obtained on a pixel-wise basis from a three fit parameter to the signal evolution. The accuracy of this method for quantifying these parameters is demonstrated in vivo. In addition, further corrections to the quantification necessary owing to other experimental factors, namely magnetization transfer and imperfect slice profiles, were developed. Including additional scans necessary for these corrections in the measurement protocol, the required scan time is increased from approximately 6 to 18-28 s per slice.

Details

show
hide
Language(s):
 Dates: 2013-01
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: URI: http://onlinelibrary.wiley.com/doi/10.1002/mrm.24225/pdf
DOI: 10.1002/mrm.24225
BibTex Citekey: EhsesSMBJGG2012
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 69 (1) Sequence Number: - Start / End Page: 71–81 Identifier: -