日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

  IR TrueFISP with a golden-ratio-based radial readout: Fast quantification of T1, T2, and proton density

Ehses, P., Seiberlich N, Ma D, Breuer FA, Jakob PM, Griswold, M., & Gulani, V. (2013). IR TrueFISP with a golden-ratio-based radial readout: Fast quantification of T1, T2, and proton density. Magnetic Resonance in Medicine, 69(1), 71–81. doi:10.1002/mrm.24225.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Ehses, P1, 著者           
Seiberlich N, Ma D, Breuer FA, Jakob PM, Griswold, MA, 著者
Gulani, V, 著者
所属:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

内容説明

表示:
非表示:
キーワード: -
 要旨: A promising approach for the simultaneous quantification of relative proton density (M0), T1, and T2 is the inversion-recovery TrueFISP sequence, consisting of an inversion pulse followed by a series of balanced steady-state free precession acquisitions. Parameters can then be obtained from a mono-exponential fit to the series of images. However, a segmented acquisition is usually necessary, which increases the total acquisition time considerably. The goal of this study is to obtain M0, T1, and T2 maps using a single-shot acquisition, with T1 and T2 measurements in brain that are consistent with the published literature, with a 20-fold speed improvement over the segmented approach, and at a clinically relevant spatial resolution. To this end, a single-shot inversion-recovery TrueFISP sequence was combined with a radial view-sharing technique. The parameters M0, T1, and T2 were then obtained on a pixel-wise basis from a three fit parameter to the signal evolution. The accuracy of this method for quantifying these parameters is demonstrated in vivo. In addition, further corrections to the quantification necessary owing to other experimental factors, namely magnetization transfer and imperfect slice profiles, were developed. Including additional scans necessary for these corrections in the measurement protocol, the required scan time is increased from approximately 6 to 18-28 s per slice.

資料詳細

表示:
非表示:
言語:
 日付: 2013-01
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): URI: http://onlinelibrary.wiley.com/doi/10.1002/mrm.24225/pdf
DOI: 10.1002/mrm.24225
BibTex参照ID: EhsesSMBJGG2012
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Magnetic Resonance in Medicine
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: 69 (1) 通巻号: - 開始・終了ページ: 71–81 識別子(ISBN, ISSN, DOIなど): -