English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Theoretical study of multicomponent continuous countercurrent chromatography based on connected 4-zone units

Keßler, L. C., & Seidel-Morgenstern, A. (2006). Theoretical study of multicomponent continuous countercurrent chromatography based on connected 4-zone units. Journal of Chromatography A, 1126(1-2), 323-337. doi:10.1016/j.chroma.2006.05.012.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Keßler, L. C.1, Author           
Seidel-Morgenstern, A.1, 2, Author           
Affiliations:
1Physical and Chemical Foundations of Process Engineering, Max Planck Institute for Dynamics of Complex Technical Systems, Max Planck Society, ou_1738150              
2Otto-von-Guericke-Universität Magdeburg, External Organizations, ou_1738156              

Content

show
hide
Free keywords: -
 Abstract: Continuous countercurrent or simulated moving bed (SMB) chromatography is a well-established separation technology. Conventional processes are based on four zones which fulfil distinct functions in order to split a feed into two fractions. Frequently there is an interest in isolating a target component out of a feed mixture containing more than two components. Modifications of the classical SMB process are required to solve this task. In the last years several concepts exploiting more than four zones have been suggested. To analyse these concepts the equilibrium theory has been frequently applied, neglecting all kinetic effects. It is the purpose of this paper to apply an equilibrium stage model in order to describe the performance of a combination of two or three 4-zone true moving bed units which are connected in series or integrated into 8- or 12-zone true moving bed units. The performance of such units is evaluated with respect to their potential to continuously separate ternary or quaternary mixtures. The analysis is based on the assumption of linear adsorption isotherms. An important aspect is the introduction of additional purge streams required for a successful operation of integrated 8- and 12-zone units. 2006 Elsevier Inc. All rights reserved [accessed 2013 November 27th]

Details

show
hide
Language(s): eng - English
 Dates: 2006
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: eDoc: 286998
Other: 16/06
DOI: 10.1016/j.chroma.2006.05.012
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Journal of Chromatography A
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Amsterdam : Elsevier
Pages: - Volume / Issue: 1126 (1-2) Sequence Number: - Start / End Page: 323 - 337 Identifier: ISSN: 0021-9673
CoNE: https://pure.mpg.de/cone/journals/resource/954925527837_1