English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Iterative learning control for correction of drop- foot using bio-impedance as sensory information

Nahrstaedt, H., Schauer, T., Hesse, S., & Raisch, J. (2007). Iterative learning control for correction of drop- foot using bio-impedance as sensory information. Artificial Organs, 31(8), A1-A30.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Nahrstaedt, Holger1, Author
Schauer, Thomas1, Author
Hesse, Stefan2, Author
Raisch, Jörg1, 3, Author           
Affiliations:
1TU Berlin, ou_persistent22              
2Charité—University Hospital Berlin, ou_persistent22              
3Systems and Control Theory, Max Planck Institute for Dynamics of Complex Technical Systems, Max Planck Society, ou_1738154              

Content

show
hide
Free keywords: -
 Abstract: Automatic control of ankle-joint angle for the correction of drop-foot has been investigated using Bio-Impedance (BI) for measuring the joint angle and Iterative Learning Control (ILC) for adjusting the stimulation profile. A customised four-channel measurement system (50 kHz) was used to assess bio-impedance changes caused by ankle-joint motion. Two current excitation electrodes were placed below the patella on the shank and on the dorsum of the foot. Voltage detection electrodes were attached to the posterior surface of lower leg below the calf and on the M. tibialis anterior close to its origin. A demodulation circuit determines changes in the absolute value of the BI from the measured and amplified voltage. All circuits are protected against stimulation artefacts so that the recording of BI is possible while muscle stimulation is active. Calibration of the angle measurement was performed by positioning the ankle joint at three known angles. Reference measurements were taken with a marker-based optical system. Dorsiflexion of the unconstrained ankle joint was achieved by stimulation of the M. tibialis anterior. First-order ILC was applied to realise a pre-defined angle profile in a cycle-to-cycle manner. The new stimulation intensity profile will be an update of the last profile taking tracking errors of the last cycle into account. Preliminary experiments were conducted with one able-bodied subject. An almost linear correlation between ankle-joint angle and bio-impedance was found for the angle range applicable during gait. The chosen angle trajectory (sine half-wave from the resting foot to 0 degree) was realised by the ILC within 3 cycles. The final root mean square tracking error was below 5 degree. Automatic control of ankle-joint angle by ILC is feasible when using bio-impedance as sensory information. Experiments under real walking conditions and with stroke patients must be conducted in future.

Details

show
hide
Language(s): eng - English
 Dates: 2007
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: eDoc: 327611
DOI: 10.1111/j.1525-1594.2007.00463.x
 Degree: -

Event

show
hide
Title: 9th Vienna International Workshop on Functional Electrical Stimulation
Place of Event: Krems, Austria
Start-/End Date: 2007-09-19 - 2007-09-20

Legal Case

show

Project information

show

Source 1

show
hide
Title: Artificial Organs
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 31 (8) Sequence Number: - Start / End Page: A1 - A30 Identifier: -

Source 2

show
hide
Title: Proceedings of the 9th Vienna International Workshop on Functional Electrical Stimulation
Source Genre: Proceedings
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: - Sequence Number: - Start / End Page: - Identifier: -