Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Characterization of Saturates, Aromatics, Resins, and Asphaltenes Heavy Crude Oil Fractions by Atmospheric Pressure Laser Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry

Gaspar, A., Zellermann, E., Lababidi, S., Reece, J. N., & Schrader, W. (2012). Characterization of Saturates, Aromatics, Resins, and Asphaltenes Heavy Crude Oil Fractions by Atmospheric Pressure Laser Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. ENERGY & FUELS, 26(6), 3481-3487. doi:10.1021/ef3001407.

Item is

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Gaspar, Andras1, Autor           
Zellermann, Elio1, Autor           
Lababidi, Sami1, Autor           
Reece, Jennifer Nicole1, Autor           
Schrader, Wolfgang1, Autor           
Affiliations:
1Service Department Schrader (MS), Max-Planck-Institut für Kohlenforschung, Max Planck Society, ou_1445629              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: In this study, a heavy crude oil sample was separated on the basis of solubility and polarity, resulting in saturates, aromatics, resins, and asphaltenes (SARA) fractions. The fractions were analyzed by Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) coupled to atmospheric pressure laser ionization (APLI). On the basis of the APLI–FT-ICR MS results, the molecular formulas and their corresponding aromaticity were compared to the bulk crude oil. The maltenes showed almost identical compound class distribution to the bulk sample, while the subfractions of the maltenes denoted unique distributions in compound classes and aromaticity. The aromaticity distributions of the fractions were in good agreement with expectations; however, the resins fraction showed higher aromaticity than the aromatics fraction. The potential of the SARA fractionation method as a sample-simplification tool that allows for a reduction of components present during the measurements was also demonstrated using APLI–FT-ICR MS.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2012
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1021/ef3001407
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: ENERGY & FUELS
  Andere : Energy Fuels
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Washington, D.C. : The Society
Seiten: - Band / Heft: 26 (6) Artikelnummer: - Start- / Endseite: 3481 - 3487 Identifikator: ISSN: 0887-0624
CoNE: https://pure.mpg.de/cone/journals/resource/954925553390
DOI: 10.1021/ef3001407