Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Anomalous dynamic backaction in interferometers

Tarabrin, S. P., Khalili, F. Y., Kaufer, H., Schnabel, R., & Hammerer, K. (2013). Anomalous dynamic backaction in interferometers. Physical Review A, 88: 023809. doi:10.1103/PhysRevA.88.023809.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel
Andere : Anomalous dynamic back-action in interferometers: beyond the scaling law

Dateien

einblenden: Dateien
ausblenden: Dateien
:
1212.6242 (Preprint), 545KB
Name:
1212.6242
Beschreibung:
File downloaded from arXiv at 2013-03-25 14:15
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
:
PRA88_023809.pdf (beliebiger Volltext), 779KB
Name:
PRA88_023809.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Tarabrin, Sergey P., Autor
Khalili, Farid Ya., Autor
Kaufer, Henning1, Autor           
Schnabel, R.1, Autor           
Hammerer, Klemens1, Autor
Affiliations:
1Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society, ou_24010              

Inhalt

einblenden:
ausblenden:
Schlagwörter: Quantum Physics, quant-ph, Condensed Matter, Mesoscale and Nanoscale Physics, cond-mat.mes-hall,General Relativity and Quantum Cosmology, gr-qc, Physics, Optics, physics.optics
 Zusammenfassung: We analyze dynamic optomechanical back-action effects in signal-recycled Michelson and Michelson-Sagnac interferometers that are operated off dark port. Up to now, their optomechanics has been studied under dark port condition only. For the dark port case and in the context of gravitational wave detectors, the `scaling law' assured that all back-action effects can be understood on the basis of the much simpler topology of a Fabry-Perot interferometer. Off dark port, our theoretical and experimental analysis reveals certain `anomalous' features as compared to the ones of `canonical' back-action, obtained within the scope of scaling law. In particular, optical damping as a function of detuning acquires a non-zero value on cavity resonance, and several stability/instability regions on either side of the cavity resonance appear. We report on the experimental observation of these instabilities on both sides of the cavity resonance in a Michelson-Sagnac interferometer with a micromechanical membrane. For a certain region of parameters, a stable optical spring (that is positive shifts of frequency and damping) in a free-mass interferometer with a single laser drive are possible. Our results can find implementations in both cavity optomechanics, revealing new regimes of cooling of micromechanical oscillators, and in gravitational-wave detectors, revealing the possibility of stable single-carrier optical spring which can be utilized for the reduction of quantum noise in future-generation detectors.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2012-12-262013
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: arXiv: 1212.6242
DOI: 10.1103/PhysRevA.88.023809
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Physical Review A
  Andere : Phys. Rev. A
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: New York, NY : American Physical Society
Seiten: - Band / Heft: 88 Artikelnummer: 023809 Start- / Endseite: - Identifikator: ISSN: 1050-2947
CoNE: https://pure.mpg.de/cone/journals/resource/954925225012_2