Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Simultaneous determination of the quantity and isotopic signature of dissolved organic matter from soil water using high-performance liquid chromatography/isotope ratio mass spectrometry

Scheibe, A., Krantz, L., & Gleixner, G. (2012). Simultaneous determination of the quantity and isotopic signature of dissolved organic matter from soil water using high-performance liquid chromatography/isotope ratio mass spectrometry. Rapid Communications in Mass Spectrometry, 26(2), 173-180. doi:10.1002/rcm.5311.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
BGC1633.pdf (Verlagsversion), 990KB
 
Datei-Permalink:
-
Name:
BGC1633.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Eingeschränkt (Max Planck Institute for Biogeochemistry, MJBK; )
MIME-Typ / Prüfsumme:
application/octet-stream
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Scheibe, Andrea1, Autor           
Krantz, Lars1, Autor           
Gleixner, Gerd1, Autor           
Affiliations:
1Molecular Biogeochemistry Group, Dr. G. Gleixner, Department Biogeochemical Processes, Prof. S. E. Trumbore, Max Planck Institute for Biogeochemistry, Max Planck Society, ou_1497775              

Inhalt

einblenden:
ausblenden:
Schlagwörter: terrestrial ecosystems carbon isotopes c-13 analysis delta-c-13 dynamics analyzer nitrogen forest stream sugars
 Zusammenfassung: We assessed the accuracy and utility of a modified high-performance liquid chromatography/isotope ratio mass spectrometry (HPLC/IRMS) system for measuring the amount and stable carbon isotope signature of dissolved organic matter (DOM) < 1 mu m. Using a range of standard compounds as well as soil solutions sampled in the field, we compared the results of the HPLC/IRMS analysis with those from other methods for determining carbon and C-13 content. The conversion efficiency of the in-line wet oxidation of the HPLC/IRMS averaged 99.3 % for a range of standard compounds. The agreement between HPLC/IRMS and other methods in the amount and isotopic signature of both standard compounds and soil water samples was excellent. For DOM concentrations below 10 mg C L-1 (250 ng C total) pre-concentration or large volume injections are recommended in order to prevent background interferences. We were able to detect large differences in the C-13 signatures of soil solution DOM sampled in 10 cm depth of plots with either C3 or C4 vegetation and in two different parent materials. These measurements also demonstrated changes in the C-13 signature that demonstrate rapid loss of plant-derived C with depth. Overall the modified HLPC/IRMS system has the advantages of rapid sample preparation, small required sample volume and high sample throughput, while showing comparable performance with other methods for measuring the amount and isotopic signature of DOM. Copyright (C) 2011 John Wiley & Sons, Ltd.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2012
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1002/rcm.5311
ISI: ://WOS:000299738500009
Anderer: BGC1633
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Rapid Communications in Mass Spectrometry
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: New York, NY : John Wiley & Sons
Seiten: - Band / Heft: 26 (2) Artikelnummer: - Start- / Endseite: 173 - 180 Identifikator: CoNE: https://pure.mpg.de/cone/journals/resource/954925574961
ISSN: 0951-4198