  Quality control of CarboEurope flux data - Part 2: inter-comparison of eddy-covariance software

Mauder, M., Foken, T., Clement, R., Elbers, J. A., Eugster, W., Grunwald, T., et al. (2008). Quality control of CarboEurope flux data - Part 2: inter-comparison of eddy-covariance software. Biogeosciences, 5(2), 451-462. doi:10.5194/bg-5-451-2008.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
BGC1116.pdf (Verlagsversion), 509KB
Name:
BGC1116.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/octet-stream / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-
:
BGC1116D.pdf (Preprint), 735KB
Name:
BGC1116D.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/octet-stream / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:
ausblenden:
externe Referenz:
http://dx.doi.org/10.5194/bg-5-451-2008 (Verlagsversion)
Beschreibung:
OA
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Mauder, M., Autor
Foken, T., Autor
Clement, R., Autor
Elbers, J. A., Autor
Eugster, W., Autor
Grunwald, T., Autor
Heusinkveld, B., Autor
Kolle, O.1, Autor           
Affiliations:
1Service Facility Field Measurements & Instrumentation, O. Kolle, Max Planck Institute for Biogeochemistry, Max Planck Society, ou_1497769              

Inhalt

einblenden:
ausblenden:
Schlagwörter: Energy-balance closure Frequency-response corrections Anemometer (co)sine response Net ecosystem exchange Sonic anemometer CO2 fluxes Open-path Scalar similarity Tall vegetation Water-vapor
 Zusammenfassung: As part of the quality assurance and quality control activities within the CarboEurope-IP network, a comparison of eddy-covariance software was conducted. For four five-day datasets, CO2 flux estimates were calculated by seven commonly used software packages to assess the uncertainty of CO2 flux estimates due to differences in post-processing. The datasets originated from different sites representing different commonly applied instrumentation and different canopy structures to cover a wide range of realistic conditions. Data preparation, coordinate rotation and the implementation of the correction for high frequency spectral losses were identified as crucial processing steps leading to significant discrepancies in the CO2 flux results. The overall comparison indicated a good although not yet perfect agreement among the different software within 5-10% difference for 30-min CO2 flux values. Conceptually different ideas about the selection and application of processing steps were a main reason for the differences in the CO2 flux estimates observed. A balance should be aspired between scientific freedom on the one hand, in order to advance methodical issues, and standardisation of procedures on the other hand, in order to obtain comparable fluxes for multi-site synthesis studies. [References: 54]

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2008
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: Anderer: BGC1116
DOI: 10.5194/bg-5-451-2008
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Biogeosciences
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Katlenburg-Lindau, Germany : Copernicus GmbH on behalf of the European Geosciences Union
Seiten: - Band / Heft: 5 (2) Artikelnummer: - Start- / Endseite: 451 - 462 Identifikator: CoNE: https://pure.mpg.de/cone/journals/resource/111087929276006
ISSN: 1726-4170