  Improved isotope ratio measurement performance in liquid chromatography/isotope ratio mass spectrometry by removing excess oxygen

Hettmann, E., Brand, W. A., & Gleixner, G. (2007). Improved isotope ratio measurement performance in liquid chromatography/isotope ratio mass spectrometry by removing excess oxygen. Rapid Communications in Mass Spectrometry, 21(24), 4135-4141. doi:10.1002/rcm.3304.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
BGC1236.pdf (Verlagsversion), 233KB
 
Datei-Permalink:
-
Name:
BGC1236.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Eingeschränkt (Max Planck Institute for Biogeochemistry, MJBK; )
MIME-Typ / Prüfsumme:
application/octet-stream
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Hettmann, E.1, Autor           
Brand, W. A.2, Autor           
Gleixner, G.1, Autor           
Affiliations:
1Molecular Biogeochemistry Group, Dr. G. Gleixner, Department Biogeochemical Processes, Prof. E.-D. Schulze, Max Planck Institute for Biogeochemistry, Max Planck Society, ou_1497773              
2Service Facility Stable Isotope/Gas Analytics, Dr. W. A. Brand, Max Planck Institute for Biogeochemistry, Max Planck Society, ou_1497772              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: A low dead volume oxygen scrubbing system was introduced in a commercially available liquid chromatography/isotope ratio mass spectrometry (LC/IRMS) interface to enhance the analytical capability of the system. In the LC/IRMS interface carbon from organic samples is converted into CO2 inside the mobile phase by wet chemical oxidation using peroxodisulfate (Na2S2O8). After passing the hot reaction zone, surplus oxygen (O-2) remains dissolved in the liquid phase. Both CO2 and O-2 diffuse through a transfer membrane into the helium carrier and are transferred to the mass spectrometer. The presence of O-2 in the ion source may have detrimental effects on measurement accuracy and precision as well as on filament lifetime. As a remedy, a new on-line O-2-removing device has been incorporated into the system. The new O-2 scrubber consists of two parallel hot copper reduction reactors (0.8 mm i.d., active length 120mm) and a switch-over valve between them. One reactor is regenerated using He/H-2 while the other is actively scavenging O-2 from the gas stream. The capacity of each reduction reactor, expressed as usage time, is between 40 and 50 min. This is sufficient for a single LC run for sugars and organic acids. A further increase of the reduction capacity is accompanied by a peak broadening of about 100%. After switching to a freshly reduced reactor the oxygen background and the delta C-13 values of the reference gas need up to 500 s to stabilize. For repeated injections the delta C-13 values of sucrose remain constant (+/- 0.1 parts per thousand) for about 3000 s. The long-term stability for measurements of sucrose was 0.11 parts per thousand without the reduction oven and improved slightly to 0.08 parts per thousand with the reduction oven. The filament lifetime improved by more than 600%, thereby improving the long-term system stability and analytical efficiency. In addition the costs per analysis were reduced considerably.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2007
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1002/rcm.3304
Anderer: BGC1236
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Rapid Communications in Mass Spectrometry
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: New York, NY : John Wiley & Sons
Seiten: - Band / Heft: 21 (24) Artikelnummer: - Start- / Endseite: 4135 - 4141 Identifikator: CoNE: https://pure.mpg.de/cone/journals/resource/954925574961
ISSN: 0951-4198