Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Compound-specific stable carbon isotope ratios (δ13C values) of the halogenated natural product 2,3,3',4,4',5,5'-heptachloro-1'-methyl-1,2'-bipyrrole (Q1)

Vetter, W., & Gleixner, G. (2006). Compound-specific stable carbon isotope ratios (δ13C values) of the halogenated natural product 2,3,3',4,4',5,5'-heptachloro-1'-methyl-1,2'-bipyrrole (Q1). Rapid Communications in Mass Spectrometry, 20(20), 3018-3022. doi:10.1002/rcm.2686.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
BGC1215.pdf (Verlagsversion), 117KB
 
Datei-Permalink:
-
Name:
BGC1215.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Eingeschränkt (Max Planck Institute for Biogeochemistry, MJBK; )
MIME-Typ / Prüfsumme:
application/octet-stream
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Vetter, W., Autor
Gleixner, G.1, Autor           
Affiliations:
1Molecular Biogeochemistry Group, Dr. G. Gleixner, Department Biogeochemical Processes, Prof. E.-D. Schulze, Max Planck Institute for Biogeochemistry, Max Planck Society, ou_1497773              

Inhalt

einblenden:
ausblenden:
Schlagwörter: GAS-CHROMATOGRAPHY ORGANOHALOGEN COMPOUNDS MASS-SPECTROMETRY ORGANOCHLORINE MIXTURES CHLORINE SEAL
 Zusammenfassung: Compound-specific isotope analysis using gas chromatography interfaced to isotope ratio mass spectrometry (GC/IRMS) was applied for the determination of delta C-13 values of the marine halogenated natural product 2,3,3',4,4',5,5'-heptachloro-1'-methyl-1,2'(.)bipyrrole (Q1) The delta C-13 value of a labmade Q1 standard (-34.20 +/- 0.27 parts per thousand) was depleted in C-13 by more than 11 parts per thousand relative to the residues of Q1 in dolphin blubber from Australia and skua liver from Antarctica. This clarified that the synthesized Q1 was not the source for Q1 in the biota samples. However, two Australian marine mammals showed a large variation in the delta C-13 value, which, in our experience, was implausible. Since the GC/IRMS system was connected to a conventional ion trap mass spectrometer by a post-column splitter, we were able to closely inspect the peak purity of Q1 in the respective samples. While the mass spectra of Q1 did not indicate any impurity, a fronting peak of PCB 101 was identified in one sample. This interference falsified the delta C-13 value of the respective sample. Once this sample was excluded, we found that the delta C-13 values of the remaining samples, i.e. liver of Antarctic brown skua (-21.47 +/- 1.47 parts per thousand) and blubber of Australian melon-headed whale (-22.80 +/- 0.33 parts per thousand), were in the same order. The standard deviation for Q1 was larger in the skua samples than in the standard and the whale blubber sample. This was due to lower amounts of skua sample available. It remained unclear if the Q1 residues originate from the same producer and location. Copyright (c) 2006 John Wiley & Sons, Ltd.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2006
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1002/rcm.2686
ISI: ://000241332500003
Anderer: BGC1215
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Rapid Communications in Mass Spectrometry
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: New York, NY : John Wiley & Sons
Seiten: - Band / Heft: 20 (20) Artikelnummer: - Start- / Endseite: 3018 - 3022 Identifikator: CoNE: https://pure.mpg.de/cone/journals/resource/954925574961
ISSN: 0951-4198