  Gas chromatography/isotope-ratio mass spectrometry method for high-precision position-dependent 15N and 18O measurements of atmospheric nitrous oxide

Röckmann, T., Kaiser, J., Brenninkmeijer, C. A. M., & Brand, W. A. (2003). Gas chromatography/isotope-ratio mass spectrometry method for high-precision position-dependent 15N and 18O measurements of atmospheric nitrous oxide. Rapid Communications in Mass Spectrometry, 17(16), 1897-1908.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
BGC0629.pdf (Verlagsversion), 301KB
 
Datei-Permalink:
-
Name:
BGC0629.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Eingeschränkt (Max Planck Institute for Biogeochemistry, MJBK; )
MIME-Typ / Prüfsumme:
application/octet-stream
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Röckmann, T., Autor
Kaiser, J., Autor
Brenninkmeijer, C. A. M., Autor
Brand, W. A.1, Autor           
Affiliations:
1Service Facility Stable Isotope/Gas Analytics, Dr. W. A. Brand, Max Planck Institute for Biogeochemistry, Max Planck Society, ou_1497772              

Inhalt

einblenden:
ausblenden:
Schlagwörter: Oxygen-isotope ratios; o-17/o-16 ratios; N2O isotopomers; site preference; fractionation; photolysis; nitrification; stratosphere; (nno)-n-14-n-15-o-16; (nno)-n-15-n-14-o-16
 Zusammenfassung: We describe an automated gas chromatography/isotope-ratio mass spectrometry (GC/IRMS) method for the determination of the O-18 and position-resolved N-15 content of nitrous oxide at natural isotope abundance. The position information is obtained from successive measurement of the isotopic composition of the N2O+ ion at m/z 44, 45, 46 and the NO+ fragment ion at m/z 30, 31. The fragment ion analysis is complicated by a non-linearity in the mass spectrometer that has to be taken into account. Evaluation of the absolute peak areas allows for a simultaneous determination of the N2O mixing ratio for atmospheric samples. Samples with mixing ratios ranging from a few nmol/mol up to the percent level can be analyzed using different sample inlet systems. The high concentration inlet system provides an easy and quick method to carry out various diagnostic tests, in particular to perform realistic linearity tests. A gas chromatographic set-up with a split column and a backflush possibility improves analytical precision and excludes interferences by substances with long retention times from preceding runs. We also describe a new open split interface that uses only a single transfer capillary to the mass spectrometer for sample and reference gas. Copyright (C) 2003 John Wiley Sons, Ltd.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2003
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: Anderer: BGC0629
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Rapid Communications in Mass Spectrometry
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: New York, NY : John Wiley & Sons
Seiten: - Band / Heft: 17 (16) Artikelnummer: - Start- / Endseite: 1897 - 1908 Identifikator: CoNE: https://pure.mpg.de/cone/journals/resource/954925574961
ISSN: 0951-4198