English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  ConFlo III - An interface for high precision δ 13C and δ 15N analysis with an extended dynamic range

Werner, R. A., Bruch, B. A., & Brand, W. A. (1999). ConFlo III - An interface for high precision δ 13C and δ 15N analysis with an extended dynamic range. Rapid Communications in Mass Spectrometry, 13(13), 1237-1241.

Item is

Files

show Files
hide Files
:
BGC0194.pdf (Publisher version), 84KB
 
File Permalink:
-
Name:
BGC0194.pdf
Description:
-
OA-Status:
Visibility:
Restricted (Max Planck Institute for Biogeochemistry, MJBK; )
MIME-Type / Checksum:
application/octet-stream
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show

Creators

show
hide
 Creators:
Werner, R. A.1, Author           
Bruch, Beate A.1, Author           
Brand, W. A.1, Author           
Affiliations:
1Service Facility Stable Isotope/Gas Analytics, Dr. W. A. Brand, Max Planck Institute for Biogeochemistry, Max Planck Society, ou_1497772              

Content

show
hide
Free keywords: Ratio mass-spectrometer Elemental analyzer Online determination Organic-substances Isotope Nitrogen Matter Water o-18
 Abstract: A newly developed interface coupling a CHN combustion device (elemental analyser 'EA') to an isotope ratio mass spectrometer is described and evaluated. The purpose of the device is to extend the dynamic range of delta(13)C and delta(15)N analysis from less than 2 orders of magnitude to more than 3 orders of magnitude. Carbon isotope ratio measurements of atropine as a model compound have been performed analysing between 1 mu g to 5 mg C with acceptable to excellent precision (0.6 to 0.06 parts per thousand, delta-notation). The correction due to the blank signal is critical for sample amounts smaller than 4 mu g C. The maximum sample weight is determined by the combustion capacity of the EA, Larger sample amounts are measured using dilution of a small part of the EA effluent with helium. The dilution mechanism works virtually free of isotope fractionation, Copyright (C) 1999 John Wiley & Sons, Ltd. [References: 19]

Details

show
hide
Language(s):
 Dates: 1999
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: Other: BGC0194
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Rapid Communications in Mass Spectrometry
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: New York, NY : John Wiley & Sons
Pages: - Volume / Issue: 13 (13) Sequence Number: - Start / End Page: 1237 - 1241 Identifier: CoNE: https://pure.mpg.de/cone/journals/resource/954925574961
ISSN: 0951-4198