Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Standardization for oxygen isotope ratio measurement - Still an unsolved problem

Kornexl, B. E., Werner, R. A., & Gehre, M. (1999). Standardization for oxygen isotope ratio measurement - Still an unsolved problem. Rapid Communications in Mass Spectrometry, 13(13), 1248-1251.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
BGC0156.pdf (Verlagsversion), 46KB
 
Datei-Permalink:
-
Name:
BGC0156.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Eingeschränkt (Max Planck Institute for Biogeochemistry, MJBK; )
MIME-Typ / Prüfsumme:
application/octet-stream
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Kornexl, B. E., Autor
Werner, R. A.1, Autor           
Gehre, M., Autor
Affiliations:
1Service Facility Stable Isotope/Gas Analytics, Dr. W. A. Brand, Max Planck Institute for Biogeochemistry, Max Planck Society, ou_1497772              

Inhalt

einblenden:
ausblenden:
Schlagwörter: Online determination Organic-substances o-18 Fractionation Carbonates O-18/o-16 Delta-o-18 Pyrolysis Nitrate Matter
 Zusammenfassung: Numerous organic and inorganic laboratory standards were gathered from nine European and North American laboratories and were analyzed for their delta(18)O values with a new on-line high temperature pyrolysis system that was calibrated using Vienna standard mean ocean water (VSMOW) and standard light Antartic precipitation (SLAP) internationally distributed reference water samples. Especially for organic materials, discrepancies between reported and measured values were high, ranging up to 2 parts per thousand. The reasons for these discrepancies are discussed and the need for an exact and reliable calibration of existing reference materials, as well as for the establishment of additional organic and inorganic reference materials is stressed. Copyright (C) 1999 John Whey & Sons, Ltd. [References: 41]

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 1999
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: Anderer: BGC0156
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Rapid Communications in Mass Spectrometry
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: New York, NY : John Wiley & Sons
Seiten: - Band / Heft: 13 (13) Artikelnummer: - Start- / Endseite: 1248 - 1251 Identifikator: CoNE: https://pure.mpg.de/cone/journals/resource/954925574961
ISSN: 0951-4198