  A cryogenic detection system at 28.9MHz for the non-destructive observation of a single proton at low particle energy

Ulmer, S., Blaum, K., Kracke, H., Mooser, A., Quint, W., Rodegheri, C. C., et al. (2012). A cryogenic detection system at 28.9MHz for the non-destructive observation of a single proton at low particle energy. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 705, 55-60. doi:10.1016/j.nima.2012.12.071.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Ulmer, S.1, Author
Blaum, Klaus2, 3, Author           
Kracke, H.4, 5, Author
Mooser, A.4, 5, Author
Quint, W.3, 6, Author
Rodegheri, Cricia C.2, 4, Author           
Walz, J.5, 6, Author
Affiliations:
1RIKEN AdvancedScienceInstitute,Hirosawa, Wako,Saitama351-0198,Japan, ou_persistent22              
2Division Prof. Dr. Klaus Blaum, MPI for Nuclear Physics, Max Planck Society, ou_904548              
3Ruprecht Karls-Universität Heidelberg, D-69047Heidelberg,Germany, ou_persistent22              
4Institut für Physik,JohannesGutenberg-Universität, D-55099Mainz,Germany, ou_persistent22              
5Helmholtz Institut Mainz, D-55099Mainz,Germany, ou_persistent22              
6GSI Helmholtzzentrum für Schwerionenforschung, D-64291Darmstadt,Germany, ou_persistent22              

Content

show
hide
Free keywords: -
 Abstract: A highly sensitive detection system for the non-destructive measurement of the cyclotron frequency of a single proton stored in a cryogenic Penning trap is described. The detector consists of a low noise GaAs field effect transistor amplifier combined with a copper helical resonator with high quality factor. The resonance frequency can be tuned with a GaAs-varactor diode. Connected to the Penning trap a quality factor of 1250 at 28.9 MHz is achieved. With this detection system the signal of a single proton at a cyclotron mode-energy of only 10 meV was resolved.

Details

show
hide
Language(s): eng - English
 Dates: 2012-12-20
 Publication Status: Published online
 Pages: 6
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.1016/j.nima.2012.12.071
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  Other : Nucl. Instrum. Methods Phys. Res. A
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: North-Holland
Pages: - Volume / Issue: 705 Sequence Number: - Start / End Page: 55 - 60 Identifier: ISSN: 0168-9002
CoNE: https://pure.mpg.de/cone/journals/resource/954925485716