English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Unraveling the structure of membrane proteins in situ by transfer function corrected cryo-electron tomography

Eibauer, M., Hoffmann, C., Plitzko, J. M., Baumeister, W., Nickell, S., & Engelhardt, H. (2012). Unraveling the structure of membrane proteins in situ by transfer function corrected cryo-electron tomography. JOURNAL OF STRUCTURAL BIOLOGY, 180(3), 488-496. doi:10.1016/j.jsb.2012.09.008.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Eibauer, Matthias1, Author           
Hoffmann, Christian1, Author           
Plitzko, Jürgen M.1, Author           
Baumeister, Wolfgang1, Author           
Nickell, Stephan1, Author           
Engelhardt, Harald1, Author           
Affiliations:
1Baumeister, Wolfgang / Molecular Structural Biology, Max Planck Institute of Biochemistry, Max Planck Society, ou_1565142              

Content

show
hide
Free keywords: PARTICLE ELECTRON CRYOMICROSCOPY; MYCOBACTERIAL OUTER-MEMBRANE; MOLECULAR ARCHITECTURE; ENVELOPE PROTEIN; 26S PROTEASOME; CELL-WALL; MICROSCOPY; SMEGMATIS; RESOLUTION; COMPLEXCryo-electron microscopy; 3D electron microscopy; Contrast transfer function (CTF); Modulation transfer function (MTF); Subtomogram averaging; Porin; Outer membrane protein; Mycobacterium smegmatis;
 Abstract: Cryo-electron tomography in combination with subtomogram averaging allows to investigate the structure of protein assemblies in their natural environment in a close to live state. To make full use of the structural information contained in tomograms it is necessary to analyze the contrast transfer function (CTF) of projections and to restore the phases of higher spatial frequencies. CTF correction is however hampered by the difficulty of determining the actual defocus values from tilt series data, which is due to the low signal-to-noise ratio of electron micrographs. In this study, an extended acquisition scheme is introduced that enables an independent CTF determination. Two high-dose images are recorded along the tilt axis on both sides of each projection, which allow an accurate determination of the defocus values of these images. These values are used to calculate the CTF for each image of the tilt series. We applied this scheme to the mycobacterial outer membrane protein MspA reconstituted in lipid vesicles and tested several variants of Cif estimation in combination with subtomogram averaging and correction of the modulation transfer function (MTF). The 3D electron density map of MspA was compared with a structure previously determined by X-ray crystallography. We were able to demonstrate that structural information up to a resolution of 16.8 angstrom can be recovered using our CTF correction approach, whereas the uncorrected 3D map had a resolution of only 26.2 angstrom. (C) 2012 Elsevier Inc. All rights reserved.

Details

show
hide
Language(s): eng - English
 Dates: 2012-12
 Publication Status: Issued
 Pages: 9
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: ISI: 000311471000011
DOI: 10.1016/j.jsb.2012.09.008
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: JOURNAL OF STRUCTURAL BIOLOGY
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: 525 B ST, STE 1900, SAN DIEGO, CA 92101-4495 USA : ACADEMIC PRESS INC ELSEVIER SCIENCE
Pages: - Volume / Issue: 180 (3) Sequence Number: - Start / End Page: 488 - 496 Identifier: ISSN: 1047-8477