  Method development and validation for the analysis of a new anti-cancer infusion solution via HPLC

Donnarumma, F., Schober, M., Greilberger, J., Matzi, V., Lindenmann, J., Maier, A., et al. (2011). Method development and validation for the analysis of a new anti-cancer infusion solution via HPLC. Journal of Separation Science, 34(2), 135-41. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/21246718.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Donnarumma, F., Author
Schober, M., Author
Greilberger, J., Author
Matzi, V., Author
Lindenmann, J., Author
Maier, A., Author
Herwig, Ralf1, Author           
Wintersteiger, R., Author
Affiliations:
1Bioinformatics (Ralf Herwig), Dept. of Vertebrate Genomics (Head: Hans Lehrach), Max Planck Institute for Molecular Genetics, Max Planck Society, ou_1479648              

Content

show
hide
Free keywords: Antineoplastic Agents/*analysis; Chromatography, High Pressure Liquid/instrumentation/*methods
 Abstract: A fast and simple HPLC method has been developed and validated for the quantification of a completely new anti-cancer drug during the manufacturing process. The combination of four compounds including alpha-ketoglutaric acid, hydroxymethylfurfural, N-acetyl-L-methionine and N-acetyl-L-selenomethionine, administered intravenously, is still in test phase but has already shown promising results in cancer therapy. HPLC separation was achieved on an RP-18 column with a gradient system. However, the highly different concentrations of the compounds required a variation in the detection wavelength within one run. In order to produce a chromatogram where peaks were comparable on a similar range scale, detection at absorption maxima for the two most concentrated components was avoided. After optimization of the gradient program it was possible to detect all four substances within 14 min in spite of their strongly different chemical structure. The method developed was validated for accuracy, repeatability, reproducibility and robustness in relation to temperature and pH of buffer. Linearity as well as the limit of detection and quantification were determined. This HPLC method was found to be precise, accurate and reproducible and can be easily used for in-line process control during the manufacture of the anti-tumour infusion solution.

Details

show
hide
Language(s):
 Dates: 2011
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: eDoc: 584682
URI: http://www.ncbi.nlm.nih.gov/pubmed/21246718
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Journal of Separation Science
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 34 (2) Sequence Number: - Start / End Page: 135 - 41 Identifier: ISSN: 1615-9314 (Electronic) 1615-9306 (Linking)