  Toward optimized antibody microarrays: a comparison of current microarray support materials

Angenend, P., Glökler, J., Murphy, D., Lehrach, H., & Cahil, D. J. (2002). Toward optimized antibody microarrays: a comparison of current microarray support materials. Analytical Biochemistry, 309(2), 253-60.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel
Alternativer Titel : Anal Biochem

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Angenend, Philipp1, Autor           
Glökler, Jörn1, Autor           
Murphy, Derek2, Autor
Lehrach, Hans1, Autor           
Cahil, Dolores J.2, Autor
Affiliations:
1Dept. of Vertebrate Genomics (Head: Hans Lehrach), Max Planck Institute for Molecular Genetics, Max Planck Society, ou_1433550              
2Max Planck Society, ou_persistent13              

Inhalt

einblenden:
ausblenden:
Schlagwörter: Antibody chip; Protein; Microarrays; High throughput; Diagnostics
 Zusammenfassung: With the advent of protein and antibody microarray technology several different coatings and protocols have been published, which may be broadly divided into two types: gel-coated surfaces and plain non-gel-coated glass or plastic surfaces, some with chemical groups attached. We have screened 11 different array surfaces of both types and compared them with respect to their detection limit, inter- and intrachip variation, and storage characteristics. Five different antibodies were immobilized onto each type of microarray support, with total protein concentrations ranging from 40 fmol to 25 amol per spot. From these results, it was seen that some antibodies were more suited for use on antibody arrays. All measurements were performed in quadruplicate, and the results revealed high signal uniformity and reproducibility of most plain glass and plastic slides. Lower detection limits were obtained with polyacrylamide-coated slides, making them more suitable for the detection of very low concentrations of antigen. All microarray coatings could be stored for a period of 8 weeks; however, improved results were seen after 2 weeks of storage. In conclusion, the results indicate the need to test each antibody to be used on an antibody array and to select the microarray coating based on experimental requirements.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2002-10-17
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: eDoc: 24697
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Analytical Biochemistry
  Alternativer Titel : Anal Biochem
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 309 (2) Artikelnummer: - Start- / Endseite: 253 - 60 Identifikator: -