Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  A comparison of oligonucleotide and cDNA-based microarray systems

Mah, N., Thelin, A., Lu, T., Nikolaus, S., Kuehbacher, T., Gurbuz, Y., et al. (2004). A comparison of oligonucleotide and cDNA-based microarray systems. Physiological Genomics, 13(16), 361-370. doi:1094-8341/04.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel
Alternativer Titel : Physiol Genomics

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Mah, Nancy, Autor
Thelin, Anders, Autor
Lu, Tim, Autor
Nikolaus, Susanna, Autor
Kuehbacher, Tanja, Autor
Gurbuz, Yesim, Autor
Eickhoff, Holger1, Autor
Kloeppel, Guenther, Autor
Lehrach, Hans2, Autor           
Mellgård, Bjoern, Autor
Costello, Christine M., Autor
Schreiber, Stefan, Autor
Affiliations:
1Max Planck Society, ou_persistent13              
2Dept. of Vertebrate Genomics (Head: Hans Lehrach), Max Planck Institute for Molecular Genetics, Max Planck Society, ou_1433550              

Inhalt

einblenden:
ausblenden:
Schlagwörter: noncommercial clone-based microarray system; commercial oligonucleotide-based microarray system; expression screening platform; cross-platform screening
 Zusammenfassung: Large-scale public data mining will become more common as public release of microarray data sets becomes a corequisite for publication. Therefore, there is an urgent need to clarify whether data from different microarray platforms are comparable. To assess the compatibility of microarray data, results were compared from the two main types of high-throughput microarray expression technologies, namely, an oligonucleotide-based and a cDNA-based platform, using RNA obtained from complex tissue (human colonic mucosa) of five individuals. From 715 sequence-verified genes represented on both platforms, 64% of the genes matched in "present" or "absent" calls made by both platforms. Calls were influenced by spurious signals caused by Alu repeats in cDNA clones, clone annotation errors, or matched probes that were designed to different regions of the gene; however, these factors could not completely account for the level of call discordance observed. Expression levels in sequence-verified, platform-overlapping genes were not related, as demonstrated by weakly positive rank order correlation. This study demonstrates that there is only moderate overlap in the results from the two array systems. This fact should be carefully considered when performing large-scale analyses on data originating from different microarray platforms.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2004-02-13
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: eDoc: 229815
DOI: 1094-8341/04
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Physiological Genomics
  Alternativer Titel : Physiol Genomics
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 13 (16) Artikelnummer: - Start- / Endseite: 361 - 370 Identifikator: ISSN: 1094-8341