  Zero-loss energy filtering under low-dose conditions using a post-column energy filter

Grimm, R., Koster, A. J., Ziese, U., Typke, D., & Baumeister, W. (1996). Zero-loss energy filtering under low-dose conditions using a post-column energy filter. Journal of Microscopy, 183(Part 1), 60-68.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Grimm, R., Author
Koster, A. J.1, Author           
Ziese, U., Author
Typke, D.1, Author           
Baumeister, W.1, Author           
Affiliations:
1External Organizations, ou_persistent22              

Content

show
hide
Free keywords: Eftem; Electron cryomicroscopy; Energy filtering; Fourier ring correlation; Low dose; Thermoplasma; Tmv; Vesicle; Zero-loss filtering.; Automatic electron tomography.; Microbiology.
 Abstract: Electron cryomicroscopy combined with energy filtering can be performed under low-dose conditions using a post-column energy filter. The microscope combined with the filter is set up such that it can be used with similar ease as a conventional microscope, the main difference being that all filter and microscope control is performed through a central computer and images are recorded with a cooled slow-scan CCD camera. The microscope can also still be used for regular imaging on film as without the filter. Owing to the 18 times post-magnification of the filter, the microscope normally has to be operated at a small magnifications, e.g. 3000x, and the beam has to be contracted to a small spot, e.g. 5 mm, in the plane of the microscope viewing screen. Computer control allows one to perform a variety of tasks automatically, such as autofocusing, thickness measurements, most-probable-loss imaging. CCD spot-scanning and tonography. The gain in contrast due to zero-loss energy filtering is analysed using visual inspection, power spectra and Fourier ring correlation. The thickness range for ice-embedded specimens in which a filter at 120 kV is most useful appears to be between 100 and 300 nm. [References: 12]

Details

show
hide
Language(s):
 Dates: 1996-07
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: eDoc: 318705
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Journal of Microscopy
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 183 (Part 1) Sequence Number: - Start / End Page: 60 - 68 Identifier: -