Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Cryogenic linear Paul trap for cold highly charged ion experiments

Schwarz, M., Versolato, O., Windberger, A., Brunner, F. R., Ballance, T., Eberle, S. N., et al. (2012). Cryogenic linear Paul trap for cold highly charged ion experiments. Review of scientific instruments, 83(8): 083115, pp. 1-10. doi:http://link.aip.org/link/doi/10.1063/1.4742770.

Item is

Externe Referenzen

einblenden:
ausblenden:
externe Referenz:
http://link.aip.org/link/doi/10.1063/1.4742770 (Verlagsversion)
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Schwarz, M.1, Autor           
Versolato, Oscar1, Autor           
Windberger, Alexander1, Autor           
Brunner, F. R.1, Autor
Ballance, T.1, Autor
Eberle, S. N.1, Autor
Ullrich, J.1, Autor           
Schmidt, P. O.2, Autor
Hansen, A. K.2, Autor
Gingell, A. D.2, Autor
Drewsen, M.2, Autor
Crespo López Urrutia, J. R.1, Autor           
Affiliations:
1Division Prof. Dr. Joachim H. Ullrich, MPI for Nuclear Physics, Max Planck Society, ou_904547              
22University of Groningen, Kernfysisch Versneller Instituut, NL-9747 AA Groningen, The Netherlands 3Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany 4Institut für Quantenoptik, Leibniz Universität Hannover, Welfengarten 1, 30167 Hannover, Germany 5Department of Physics and Astronomy, University of Aarhus, DK-8000 Aarhus C, Denmark , ou_persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: beryllium, cryogenics, particle traps, positive ions, trapped ions
 Zusammenfassung: Storage and cooling of highly charged ions require ultra-high vacuum levels obtainable by means of cryogenic methods. We have developed a linear Paul trap operating at 4 K capable of very long ion storage times of about 30 h. A conservative upper bound of the H2 partial pressure of about 10−15 mbar (at 4 K) is obtained from this. External ion injection is possible and optimized optical access for lasers is provided, while exposure to black body radiation is minimized. First results of its operation with atomic and molecular ions are presented. An all-solid state laser system at 313 nm has been set up to provide cold Be+ ions for sympathetic cooling of highly charged ions.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2012-07-112012-08-27
 Publikationsstatus: Online veröffentlicht
 Seiten: 10
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Review of scientific instruments
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Woodbury, N.Y. [etc.] : American Institute of Physics
Seiten: - Band / Heft: 83 (8) Artikelnummer: 083115 Start- / Endseite: 1 - 10 Identifikator: ISSN: 0034-6748
CoNE: https://pure.mpg.de/cone/journals/resource/991042742033452