English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Buffer-gas-free mass-selective ion centering in Penning traps by simultaneous dipolar excitation of magnetron motion and quadrupolar excitation for interconversion between magnetron and cyclotron motion

Rosenbusch, M., Blaum, K., Borgmann, C., Kreim, S., Kretzschmar, M., Lunney, D., et al. (2012). Buffer-gas-free mass-selective ion centering in Penning traps by simultaneous dipolar excitation of magnetron motion and quadrupolar excitation for interconversion between magnetron and cyclotron motion. International Journal of Mass Spectrometry, 325-327, 51-57. doi:10.1016/j.ijms.2012.06.008.

Item is

Files

show Files

Locators

show
hide
Locator:
http://dx.doi.org/10.1016/j.ijms.2012.06.008 (Publisher version)
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Rosenbusch, M.1, Author
Blaum, Klaus2, 3, Author           
Borgmann, Christopher2, Author           
Kreim, Susanne2, 4, Author           
Kretzschmar, M.5, Author
Lunney, D.6, Author
Schweikhard, Lutz1, Author
Wienholtz, F.1, Author
Wolf, R.N.1, Author
Affiliations:
1Institut für Physik, Ernst-Moritz-Arndt-Universität, 17487 Greifswald, Germany, ou_persistent22              
2Division Prof. Dr. Klaus Blaum, MPI for Nuclear Physics, Max Planck Society, ou_904548              
3Physikalisches Institut, Ruprecht-Karls-Universität, 69120 Heidelberg, Germany, ou_persistent22              
4CERN, 1211 Geneva 23, Switzerland, ou_persistent22              
5Institut für Physik, Johannes Gutenberg-Universität, 55099 Mainz, Germany, ou_persistent22              
6CSNSM/IN2P3, Université de Paris Sud, 91405 Orsay, France, ou_persistent22              

Content

show
hide
Free keywords: -
 Abstract: A new excitation scheme of the radial ion-motional modes is introduced for Penning-trap ion-cyclotron-resonance experiments. By simultaneous dipolar excitation of the magnetron motion and resonant quadrupolar excitation for the conversion between magnetron motion and cyclotron motion, a mass-selective recentering of the ions of interest is performed while all other (contaminant) ions are ejected from the trap. This new technique does not rely on the application of a buffer gas as presently used [G. Savard, St. Becker, G. Bollen, H.-J. Kluge, R.B. Moore, Th. Otto, L. Schweikhard, H. Stolzenberg, U. Wiess, Physics Letters A 158 (1991) 247] and will thus prevent charge-exchange reactions and damping of the motion that decreases mass resolving power.

Details

show
hide
Language(s): eng - English
 Dates: 2012-06-23
 Publication Status: Published online
 Pages: 7
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.1016/j.ijms.2012.06.008
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: International Journal of Mass Spectrometry
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Amsterdam : Elsevier
Pages: - Volume / Issue: 325-327 Sequence Number: - Start / End Page: 51 - 57 Identifier: ISSN: 1387-3806
CoNE: https://pure.mpg.de/cone/journals/resource/954926232412