Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Generation of MeV electrons and positrons with femtosecond pulses from a table-top laser system

Gahn, C., Tsakiris, G. D., Pretzler, G., Witte, K. J., Thirolf, P., Habs, D., et al. (2002). Generation of MeV electrons and positrons with femtosecond pulses from a table-top laser system. Physics of Plasmas, 9(3), 987-999. Retrieved from http://ojps.aip.org/getabs/servlet/GetabsServlet?prog=normal&id=PHPAEN000009000003000987000001&idtype=cvips&gifs=Yes.

Item is

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Gahn, C.1, Autor           
Tsakiris, G. D.1, 2, Autor           
Pretzler, G.1, Autor           
Witte, K. J.1, 2, Autor           
Thirolf, P., Autor
Habs, D.1, 2, Autor           
Delfin, C., Autor
Wahlstrom, C. G., Autor
Affiliations:
1Laser Plasma Physics, Max Planck Institute of Quantum Optics, Max Planck Society, ou_1445567              
2Laboratory for Attosecond Physics, Max Planck Institute of Quantum Optics, Max Planck Society, ou_1445564              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: In experiments, the feasibility was demonstrated of generating multi-MeV electrons in a form of a collimated beam utilizing a table-top laser system delivering 200 fs pulses with PL=1.2 TW and 10 Hz capability. The method uses the process of relativistic self-channeling in a high-density gas jet producing electron densities in the range of 3x1019-6x1020 cm-3. In a thorough investigation, angularly resolved and absolutely calibrated electron spectra were measured and their dependence on the plasma density, laser intensity, and gas medium was studied. For the optimum electron density of ne=2x1020cm-3 the effective temperature of the electron energy distribution and the channel length exhibit a maximum of 5 MeV and 400 μm respectively. The laser-energy to-MeV- electron efficiency is estimated to be 5%. In a second step, utilizing the multi-MeV electron beam anti-particles, namely positrons, were successfully generated in a 2 mm Pb converter. The average intensity of this new source of positrons is estimated to be equivalent to a radioactivity of 2x108 Bq and it exhibits a very favorable scaling for higher laser intensities. (C) 2002 American Institute of Physics.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2002-03
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Physics of Plasmas
  Alternativer Titel : Phys. Plasmas
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 9 (3) Artikelnummer: - Start- / Endseite: 987 - 999 Identifikator: ISSN: 1070-664X