  Endotoxins in ophthalmic viscosurgical devices

Dick, H. B., Augustin, A. J., Pakula, T., & Pfeiffer, N. (2003). Endotoxins in ophthalmic viscosurgical devices. European Journal of Ophthalmology, 13(2), 176-184.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Dick, H. B., Author
Augustin, A. J., Author
Pakula, Tadeusz1, Author           
Pfeiffer, N., Author
Affiliations:
1MPI for Polymer Research, Max Planck Society, ou_1309545              

Content

show
hide
Free keywords: ophthalmic viscosurgical devices; endotoxins; limulus amebocyte lysate assay; inflammatory reaction
 Abstract: PURPOSE. To measure the endotoxin concentration (EC) of 25 commercially available, hyaluronic acid- and hydroxypropylmethylcellulose-based (HPMC) ophthalmic viscosurgical devices (OVDs). METHODS. The in vitro Limulus amebocyte lysate (LAL) assay, which indicates the presence of endotoxins originating from gram-negative bacteria, was used to determine the EC. The procedure was performed according to the European Pharmacopoeia/USP. EC including duplicate determinations, negative controls, dilution series with control standard endotoxin, dilution series with sample extract and positive sample control. RESULTS. 16 OVDs (Amvisc(R), Amvisc(R) Plus, Biolon(R), Coatel(R), Healon(R), Healon(R) GV, Healon(R)5, HPMC Ophtal(R) L, Microvisc(R), Microvisc(R) Plus, Ocucoat(R), Provisc(R), Rayvisc(R), Viscoat(R), Visco Shield(R) 2%, Visko(R) 1.4%) had an EC under 1.2 endotoxin units/mL, five (Adatocel(R), HPMC Ophtal(R) H, LA Gel(R), Viscorneal(R), Viscorneal(R) Plus) had an EC greater than or equal to 1.2 and less than or equal to 24 EU/ml, and four (Biocorneal(R), Dispasan(R) also named Ophthalin, Dispasan(R) Plus, Visko(R), 1%) had an EC of > 24 EU/ml. DISCUSSION. To avoid viscoelastic- related inflammatory or immunological reactions, the use of pure OVDs is recommended, especially for surgical procedures with an inherent possibility of leaving viscoelastic remnants in the eye (e.g., cataract surgery, visco-canalostomy or penetrating keratoplasty).

Details

show
hide
Language(s): eng - English
 Dates: 2003-03
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: eDoc: 28377
ISI: 000181837900009
Other: P-03-123
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: European Journal of Ophthalmology
  Alternative Title : Eur. J. Ophthalmol.
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 13 (2) Sequence Number: - Start / End Page: 176 - 184 Identifier: ISSN: 1120-6721