English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Artifacts in Slab Average-Intensity-Projection Images Reformatted from JPEG 2000 Compressed Thin-Section Abdominal CT Data Sets

Kim, B., Lee, K. H., Kim, K. J., Mantiuk, R., Kim, H.-r., & Kim, Y. H. (2008). Artifacts in Slab Average-Intensity-Projection Images Reformatted from JPEG 2000 Compressed Thin-Section Abdominal CT Data Sets. American Journal of Roentgenology, 190, W342-W350. doi:10.2214/AJR.07.3405.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Kim, Bohyoung, Author
Lee, Kyoung Ho, Author
Kim, Kil Joong1, Author           
Mantiuk, Rafał2, Author
Kim, Hye-ri, Author
Kim, Young Hoon, Author
Affiliations:
1Computer Graphics, MPI for Informatics, Max Planck Society, ou_40047              
2Max Planck Society, ou_persistent13              

Content

show
hide
Free keywords: -
 Abstract: OBJECTIVE. The objective of our study was to assess the effects of compressing source thin-section abdominal CT images on final transverse average-intensity-projection (AIP) images. MATERIALS AND METHODS. At reversible, 4:1, 6:1, 8:1, 10:1, and 15:1 Joint Photographic Experts Group (JPEG) 2000 compressions, we compared the artifacts in 20 matching compressed thin sections (0.67 mm), compressed thick sections (5 mm), and AIP images (5 mm) reformatted from the compressed thin sections. The artifacts were quantitatively measured with peak signal-to-noise ratio (PSNR) and a perceptual quality metric (High Dynamic Range Visual Difference Predictor [HDR-VDP]). By comparing the compressed and original images, three radiologists independently graded the artifacts as 0 (none, indistinguishable), 1 (barely perceptible), 2 (subtle), or 3 (significant). Friedman tests and exact tests for paired proportions were used. RESULTS. At irreversible compressions, the artifacts tended to increase in the order of AIP, thick-section, and thin-section images in terms of PSNR (p < 0.0001), HDR-VDP (p < 0.0001), and the readers' grading (p < 0.01 at 6:1 or higher compressions). At 6:1 and 8:1, distinguishable pairs (grades 1-3) tended to increase in the order of AIP, thick-section, and thin-section images. Visually lossless threshold for the compression varied between images but decreased in the order of AIP, thick-section, and thin-section images (p < 0.0001). CONCLUSION. Compression artifacts in thin sections are significantly attenuated in AIP images. On the premise that thin sections are typically reviewed using an AIP technique, it is justifiable to compress them to a compression level currently accepted for thick sections.

Details

show
hide
Language(s): eng - English
 Dates: 2009-03-162008
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: eDoc: 428133
DOI: 10.2214/AJR.07.3405
URI: http://dx.doi.org/10.2214/AJR.07.3405
Other: Local-ID: C125756E0038A185-AA47A20392426CA2C125745100560E57-kim2007asaipi
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: American Journal of Roentgenology
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 190 Sequence Number: - Start / End Page: W342 - W350 Identifier: ISSN: 0361-803X